4.2 Wall mounting
SCALANCE M804PB
30
Operating Instructions, 07/2018, C79000-G8976-C496-01
4.2
Wall mounting
Note
The wall mounting must be capable of supporting four times the weight of the device, but at
least 50 N. For information on the weight, refer to the section "Technical specifications
(Page 51)".
Installation
1.
Prepare the drill holes for wall mounting. For the precise dimensions, refer to the section
"Dimension drawing (Page 55)".
2.
Secure the device to the wall with two screws. When mounting on a wall, use mounting
fittings suitable for the type of wall.
3.
Connect the power supply, refer to the section "Power supply (Page 40)".
4.
Fit the connectors for the digital input and digital output, refer to the section "Digital
input/output (Page 43)".
5.
Connect the device to the local network, refer to the section "Ethernet port (Page 46)".
6.
Connect the device to the automation system, refer to the section "MPI/DP interface
(Page 47)".
7.
Connect the terminal with as short a cable as possible ≤ 150 mm and a large cross
-
sectional area of 1.5 mm² to the functional ground of the system, see section "Terminals
(Page 20)“ and section “Grounding (Page 42)“.
Содержание SCALANCE M804PB
Страница 16: ...Safety notices SCALANCE M804PB 16 Operating Instructions 07 2018 C79000 G8976 C496 01 ...
Страница 36: ...Installation 4 6 Mounting on a pedestal SCALANCE M804PB 36 Operating Instructions 07 2018 C79000 G8976 C496 01 ...
Страница 54: ...Technical specifications SCALANCE M804PB 54 Operating Instructions 07 2018 C79000 G8976 C496 01 ...
Страница 56: ...Dimension drawing SCALANCE M804PB 56 Operating Instructions 07 2018 C79000 G8976 C496 01 Figure 7 2 Side view ...
Страница 66: ...Approvals A 3 General approvals SCALANCE M804PB 66 Operating Instructions 07 2018 C79000 G8976 C496 01 ...
Страница 68: ...Index SCALANCE M804PB 68 Operating Instructions 07 2018 C79000 G8976 C496 01 ...