Description of the device
3.5 SET button
SCALANCE M804PB
Operating Instructions, 07/2018, C79000-G8976-C496-01
25
●
Loading new firmware
If the normal procedure with the "Load & Save" menu of Web Based Management does
not work, the reset button can be used to load new firmware. This situation can occur if
there is a power outage during the normal firmware update.
–
Hold down the button until the red fault LED (F) starts to flash after approximately 3
seconds.
–
Now release the button. The bootloader waits in this state for a new firmware file that
you can download using TFTP.
You will find more information in the section "Service and Maintenance" in the
SCALANCE M-800 Web Based Management configuration manual.
●
Reset to factory defaults
–
Hold down the button until the red fault LED (F) stops flashing after approximately 10
seconds and is permanently lit.
–
Now release the button and wait until the fault LED (F) goes off again. The device then
starts automatically with the factory settings and can be reached via the IP address
192.168.1.1.
You will find more information in the section "Service and Maintenance" in the
SCALANCE M-800 Web Based Management configuration manual.
WARNING
EXPLOSION HAZARD
Do not press the SET button if there is a potentially explosive atmosphere.
Содержание SCALANCE M804PB
Страница 16: ...Safety notices SCALANCE M804PB 16 Operating Instructions 07 2018 C79000 G8976 C496 01 ...
Страница 36: ...Installation 4 6 Mounting on a pedestal SCALANCE M804PB 36 Operating Instructions 07 2018 C79000 G8976 C496 01 ...
Страница 54: ...Technical specifications SCALANCE M804PB 54 Operating Instructions 07 2018 C79000 G8976 C496 01 ...
Страница 56: ...Dimension drawing SCALANCE M804PB 56 Operating Instructions 07 2018 C79000 G8976 C496 01 Figure 7 2 Side view ...
Страница 66: ...Approvals A 3 General approvals SCALANCE M804PB 66 Operating Instructions 07 2018 C79000 G8976 C496 01 ...
Страница 68: ...Index SCALANCE M804PB 68 Operating Instructions 07 2018 C79000 G8976 C496 01 ...