2 Use
27.05.2004
•
Maximum rate of flow temperature increase
•
Minimum and maximum limitation of the flow temperature
•
Maximum limitation of the room temperature
•
Flow alarm
•
Heat demand signal can be received
•
Differential temperature limitation (DRT function)
•
Maximum limitation of the primary return temperature, can be adjusted with 4 vari-
ables
•
Limitation of power or volumetric flow by pulses
•
Suppression of hydraulic creep in the primary circuit
•
Weather-compensated raising of the reduced room temperature setpoint
•
Remote operation via room unit
2.5 D.h.w.
functions
The RVD240 is used if one or several of the following d.h.w. functions is / are required:
•
Common or separate heat exchangers for the heating circuit and for d.h.w. heating
•
D.h.w. heating with a coil type storage tank, with charging pump
•
Direct d.h.w. heating via heat exchanger
•
D.h.w. heating with coil type or stratification storage tanks, with or without mixing
valve in the intermediate circuit
•
Continuous d.h.w. heating with mixing valve
•
Flow switch with an adjustable load limit, child-proofing and adaptation to the season
•
Own time program for the release of d.h.w.
•
Optional assignment of the circulating pump to the heating circuit or the d.h.w. circuit
time program
•
Protection against cooling down with d.h.w. heating via heat exchanger
•
Legionella protection
•
Forced d.h.w. charging
•
frost protection for d.h.w.
•
Selectable priority for d.h.w. heating : Absolute, shifting or parallel
•
Manual d.h.w. charging outside the time program
•
Maximum limitation of the d.h.w. return temperature
•
Flow alarm
2.6 Auxiliary
functions
The RVD240 is used if one or several of the following functions is / are required:
•
Pump kick, periodic pump run
•
Demand-dependent control of the common flow
•
Pump overrun
•
Valve kick, periodic activation of all actuators on the secondary side
•
PWM output, control of a variable speed pump
•
Display of parameters, actual values, operating states and fault status signals
•
Alarm input
•
Analog input DC 0...10 V (display, external heat demand)
•
Digital input (heat meter, external heat demand, etc.)
•
Flow switch (including child-proofing and adaptation to the season)
•
Communication via M-bus
•
Communication via LPB (Local Process Bus)
•
Service functions
•
Pulse lock for actuators
•
Sensor test