Installing the Device
2.5 Connecting Power
1
3
2
1
Normally Open
2
Common
3
Normally Closed
Figure 2.4
Failsafe Alarm Relay Wiring
2.5
Connecting Power
The RUGGEDCOM RSG2300P supports a single AC or DC power supply, and a separate
48 VDC power supply for PoE ports.
The RUGGEDCOM RSG2300P can be equipped with either a screw-type or pluggable
terminal block, which provides power to the AC/DC power supply and PoE ports. The
screw-type terminal block is installed using Phillips screws and compression plates,
allowing either bare wire connections or crimped terminal lugs. Use #6 size ring lugs
for secure, reliable connections under severe shock or vibration.
NOTICE
Electrical hazard – risk of damage to the device
Make sure power input to the device is within the specified input range. For
information about the nominal input range for the device, refer to
Note
• Use minimum #16 gage copper wiring when connecting terminal blocks.
• For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker
must be installed.
• A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.
• It is recommended to provide a separate circuit breaker for each power supply
module.
RUGGEDCOM RSG2300P
Installation Manual, 04/2022, C79000-G8976-1047-18
13