Installing the Device
2.3.2 Mounting the Device on a DIN Rail

To secure the device to a standard 48 cm (19 in) rack, do the following:

Note

The device can be ordered with the communication ports located at the front or rear

of the device. Placing the ports at the rear allows all data and power cabling to be

installed and connected at the rear of the rack.

1. Make sure the rack mount adapters are installed on the correct side of the

chassis.
• To make the modules and ports accessible, install the rack mount adapters

at the rear of the chassis

• To make the management ports and LEDs accessible, install the rack mount

adapters at the front of the chassis

Note

The chassis features multiple mounting holes, allowing the rack mount adapters

to be installed up to 25 mm (1 in) from the face of the device.

1

2

3

3

     1    

Rear

     2    

Front

     3    

Rack Mount Adapter

Figure 2.1

Rack Mount Adapters

2. If required, install adapters on the opposite side of the device to protect from

vibrations.

3. Insert the device into the rack.
4. Secure the adapters to the rack using the supplied hardware.

2.3.2

Mounting the Device on a DIN Rail

For DIN rail installations, the RUGGEDCOM RSG2300P can be equipped with panel/

DIN rail adapters pre-installed on each side of the chassis. The adapters allow the

device to be slid onto a standard 35 mm (1.4 in) DIN rail.

NOTICE

DIN rail mounting is not recommended for constant vibration environments.

10

RUGGEDCOM RSG2300P

Installation Manual, 04/2022, C79000-G8976-1047-18

Содержание RUGGEDCOM RSG2300P

Страница 1: ...Edition 04 2022 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RSG2300P https www siemens com ruggedcom ...

Страница 2: ...d Ethernet Switches RUGGEDCOM RSG2300P Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 04 2022 C79000 G8976 1047 18 ...

Страница 3: ...those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used the...

Страница 4: ... 1 5 3 Supported Fiber Optic Cables 5 2 Installing the Device 7 2 1 General Procedure 8 2 2 Unpacking the Device 8 2 3 Mounting the Device 8 2 3 1 Mounting the Device to a Rack 9 2 3 2 Mounting the Device on a DIN Rail 10 2 3 3 Mounting the Device to a Panel 11 2 4 Connecting the Failsafe Alarm Relay 12 2 5 Connecting Power 13 2 5 1 Connecting AC or DC Power 14 2 5 2 Connecting External PoE Power ...

Страница 5: ...ions 32 5 4 Supported Networking Standards 32 5 5 Copper Ethernet Port Specifications 32 5 6 Fiber Optic Ethernet Port Specifications 33 5 7 Operating Environment 35 5 8 Mechanical Specifications 35 5 9 Dimension Drawings 35 6 Certification 39 6 1 Approvals 39 6 1 1 CSA 39 6 1 2 European Union EU 39 6 1 3 FCC 40 6 1 4 FDA CDRH 40 6 1 5 ISED 41 6 1 6 ISO 41 6 1 7 ACMA 41 6 1 8 RoHS 41 6 1 9 Other A...

Страница 6: ...pport industry siemens com cs ca en view 109482309 SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document The glossary is available online via Siemens Industry Online Support SIOS at https support industry siemens com cs ww en view 50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RSG2300P is available online at https supp...

Страница 7: ... customer service representative Training Siemens offers a wide range of educational services ranging from in house training of standard courses on networking Ethernet switches and routers to on site customized courses tailored to the customer s needs experience and application Siemens Educational Services team thrives on providing our customers with the essential practical skills to make sure use...

Страница 8: ... and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 2...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RSG2300P Installation Manual 04 2022 C79000 G8976 1047 18 ...

Страница 10: ...P additionally offers 802 3af standard Power over Ethernet PoE on up to 4 10 100BaseTx ports The RUGGEDCOM RSG2300P is an ideal solution to power and connect several Ethernet devices such as IP phones video cameras and wireless access points where AC power is not available or cost prohibitive to provide locally 1 1 Feature Highlights Power Over Ethernet PoE 4 x 10 100Base Tx IEEE 802 3af PoE ports...

Страница 11: ...e device The display panel can be located on the rear front or top of the device depending on the mounting configuration 2 4 5 3 1 6 8 7 1 Fiber or Copper Ethernet Ports 2 Copper Ethernet Port 3 Port Status Indicator LEDs 4 Mode Button 5 RS 232 Serial Console Port RJ45 6 Display Mode Indicator LEDs 7 Alarm Indicator LED 8 Power Module Indicator LEDs Figure 1 1 RUGGEDCOM RSG2300P Communication Port...

Страница 12: ...power supply is supplying power Red Power supply failure Off No power supply is installed RS 232 Console Port The serial console port is for interfacing directly with the device and accessing initial management functions For information about connecting to the device via the serial console port refer to Connecting to the Device Page 21 1 3 Required Tools and Materials The following tools and mater...

Страница 13: ...rical event communications errors or interruptions may occur but recovery is automatic Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise i e greater than 2500 V during line to ground fault conditions 1 5 2 Gigabit Ethernet 1000Base TX Cabling Recommendations The IEEE 802 3ab Gi...

Страница 14: ...d not be run in parallel for long distances and should be installed in separate conduits Power and data cables should intersect at 90 angles when necessary to reduce inductive coupling Shielded screened cabling can be used when required Care should be taken to avoid the creation of ground loops with shielded cabling 1 5 3 Supported Fiber Optic Cables The following fiber optic cable types are suppo...

Страница 15: ...Introduction 1 5 3 Supported Fiber Optic Cables 6 RUGGEDCOM RSG2300P Installation Manual 04 2022 C79000 G8976 1047 18 ...

Страница 16: ...ures other than those specified herein may result in hazardous radiation exposure NOTICE This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications test results and agency approvals and void the user s authority to operate ...

Страница 17: ...en unpacking the device do the following 1 Inspect the package for damage before opening it 2 Visually inspect each item in the package for any physical damage 3 Verify all items are included Note If any item is missing or damaged contact Siemens for assistance 2 3 Mounting the Device The RUGGEDCOM RSG2300P is designed for maximum mounting and display flexibility It can be equipped with connectors...

Страница 18: ...erating ambient temperature of the rack may be higher than the ambient temperature of the room Make sure the rack is installed in a suitable environment that can withstand the maximum ambient temperature generated by the rack Make sure each device in the rack is separated by at least one rack unit of space or 44 mm 1 75 in to promote convectional airflow Forced airflow is not required However any ...

Страница 19: ...t of the chassis Note The chassis features multiple mounting holes allowing the rack mount adapters to be installed up to 25 mm 1 in from the face of the device 1 2 3 3 1 Rear 2 Front 3 Rack Mount Adapter Figure 2 1 Rack Mount Adapters 2 If required install adapters on the opposite side of the device to protect from vibrations 3 Insert the device into the rack 4 Secure the adapters to the rack usi...

Страница 20: ...ure 2 2 DIN Rail Mounting 2 Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails 2 3 3 Mounting the Device to a Panel For panel installations the RUGGEDCOM RSG2300P can be equipped with panelDIN rail adapters pre installed on each side of the chassis The adapters allow the device to be attached to a panel using screws RUGGEDCOM RSG2300P Installati...

Страница 21: ...onditions The NO Normally Open contact is closed when the unit is powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM RSG2300P One common application for this relay is to signal an alarm if a power f...

Страница 22: ...ions or crimped terminal lugs Use 6 size ring lugs for secure reliable connections under severe shock or vibration NOTICE Electrical hazard risk of damage to the device Make sure power input to the device is within the specified input range For information about the nominal input range for the device refer to Power Supply Specifications Page 31 Note Use minimum 16 gage copper wiring when connectin...

Страница 23: ...sient suppression circuitry during testing NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to a 24 or 48 VDC power supply Damage to the power supply may occur Note Terminals 5 and 7 POWER 2 are reserved for the external PoE power supply For information about connecting the external PoE power supply refer to Connecting External PoE Power Page 16 1 Remove the term...

Страница 24: ...Terminal 7 Chassis Ground Terminal 8 Chassis Ground Connection Figure 2 5 Terminal Block Wiring 5 Connect the negative wire from the power source to the negative neutral N terminal on the terminal block 6 Install the supplied metal jumper between terminals 2 4 and 6 to connect the surge ground terminals to the chassis ground terminal The surge ground terminals are used as the ground conductor for ...

Страница 25: ...inal block cover is always installed before the device is powered 8 Install the terminal block cover 2 5 2 Connecting External PoE Power The RUGGEDCOM RSG2300P supports up to four 10 100Base TX Power over Ethernet POE Ports that require power from an external source Note For IEC 61850 compliance use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m 118 in Otherwise Siem...

Страница 26: ...from terminals 5 and 7 Use these screws along with 6 ring lugs to secure the wires to the terminal block 3 Connect the positive wire from the power source to terminal 5 L on the terminal block 3 4 3 4 1 2 3 3 1 1 Screw Type Terminal Block 2 Pluggable Terminal Block 3 Jumper 4 Terminal 4 Chassis Ground 5 Terminal 5 L 6 Terminal 7 N 7 Chassis Ground Terminal Figure 2 7 Terminal Block Wiring 4 Connec...

Страница 27: ...ion hazard risk of death serious personal injury and or damage to the device Make sure the supplied terminal block cover is always installed before the device is powered 6 Install the terminal block cover 2 5 3 Wiring Examples The following illustrate how to connect power to single and dual power supplies Figure 2 8 DC and 48 VDC PoE Power Supply 18 RUGGEDCOM RSG2300P Installation Manual 04 2022 C...

Страница 28: ...Installing the Device 2 5 3 Wiring Examples Figure 2 9 AC and 48 VDC PoE Power Supply RUGGEDCOM RSG2300P Installation Manual 04 2022 C79000 G8976 1047 18 19 ...

Страница 29: ...Installing the Device 2 5 3 Wiring Examples 20 RUGGEDCOM RSG2300P Installation Manual 04 2022 C79000 G8976 1047 18 ...

Страница 30: ...s to RUGGEDCOM RSG2300P s console and Web interfaces NOTICE The serial console port is intended to be used only as a temporary connection during initial configuration or troubleshooting Connection to the console port is made using an RJ45 to DB9 console cable The following is the pin out for the console port 1 8 Figure 3 1 RJ45 Console Port Pin Configuration Pin RJ45 Male DB9 Female Name Descripti...

Страница 31: ...nd access the RUGGEDCOM RSG2300P console and Web interfaces via the device s IP address For more information about available ports refer to Communication Ports Page 23 3 2 Configuring the Device Once the device is installed and connected to the network it must be configured All configuration management is done via the RUGGEDCOM RSG2300P interface For more information about configuring the device r...

Страница 32: ... 10 100Base TX 802 3af PoE module Slots 3 and 4 support any combination of two port Gigabit Ethernet 1 Gbps ports Slots 5 6 and 7 house 8 port 10 100TX copper RJ45 Ethernet ports totaling 24 ports The exact configuration of the device can be determined by reading the factory data file through the RUGGEDCOM RSG2300P user interface For more information about how to read the factory data file refer t...

Страница 33: ...hassis ground on the device and can accept CAT 5 shielded twisted pair STP cables WARNING Electric shock hazard risk of serious personal injury and or equipment interference If shielded cables are used make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end Ground loops can cause excessive noise and interference but more importantly create...

Страница 34: ...wer over Ethernet POE ports in slot 2 as well as an additional two ports in slot 1 PoE ports comply with the IEEE 802 3af standard and feature auto sensing and automatic power off when cables are removed PoE ports require an external 48 VDC power source For information about connecting an external power source refer to Connecting External PoE Power Page 16 Power Budget The total allowable power bu...

Страница 35: ...ot Connect Specifications For specifications on the available PoE ports refer to PoE Power Supply Specifications Page 31 4 3 Fiber Optic Ethernet Ports Fiber optic Ethernet ports are available with either MTRJ Mechanical Transfer Registered Jack LC Lucent Connector SC Standard or Subscriber Connector or ST Straight Tip connectors Make sure the Transmit Tx and Receive Rx connections of each port ar...

Страница 36: ... established Yellow Blinking Activity Off No link detected Compatible SFP Transceivers For more information about which SFP transceivers are compatible with the RUGGEDCOM RSG2300P as well as instructions for ordering and installation removal refer to the RUGGEDCOM SFP Transceiver Catalog https support industry siemens com cs ca en view 109482309 IMPORTANT Only use SFP transceivers approved by Siem...

Страница 37: ...use serious damage to the component once it is outside the chassis NOTICE Only install GBIC optical ports that are compatible with the RUGGEDCOM RSG2300P 1 Make sure all potential electrostatic build up has been properly discharged to prevent electrostatic discharges ESD This can be accomplished by wearing an ESD preventive wrist strap connected to either the chassis ground connector or a bare met...

Страница 38: ...ed with the port For more information about the LED refer to Communication Ports Page 23 4 5 2 Removing a GBIC Optical Port To remove an GBIC optical port do the following NOTICE Electrical hazard risk of damage to equipment Make sure all electrostatic energy is dissipated before performing installing or removing components from the device An electrostatic discharge ESD can cause serious damage to...

Страница 39: ...ket 2 1 3 1 Socket 2 GBIC Optical Port 3 Locking Latch Figure 4 11 Removing a GBIC Optical Port 4 Store the port in an ESD safe bag or other suitable ESD safe environment free from moisture and stored at the proper temperature 40 to 85 C or 40 to 185 F 5 Insert a dust plug into the socket opening to prevent the ingress of dust and dirt 30 RUGGEDCOM RSG2300P Installation Manual 04 2022 C79000 G8976...

Страница 40: ...al Fuse Rating ab Maximum Power Consumption c 24 VDC 10 VDC 36 VDC 6 3 A F 48 VDC 36 VDC 59 VDC 3 15 A T HI 125 250 VDC d 88 VDC 300 VDC 2 A T HI 110 230 VAC d 85 VAC 264 VAC 2 A T 25 W a F denotes fast acting fuse b T denotes time delay fuse c Power consumption varies based on configuration 10 100Base TX ports consume roughly 1 W less than fiber optic ports d The HI power supply is the same power...

Страница 41: ...es IEEE 802 1D ü ü ü Spanning Tree Protocol STP IEEE 802 1p ü ü ü Class of Service CoS IEEE 802 1Q ü ü ü VLAN Virtual LAN Tagging IEEE 802 1w ü ü ü Rapid Spanning Tree Protocol RSTP IEEE 802 1x ü ü ü Port Based Network Access Control IEEE 802 1Q 2005 formerly 802 1s ü ü ü Multiple Spanning Tree Protocol MSTP 5 5 Copper Ethernet Port Specifications The following details the specifications for coppe...

Страница 42: ... Sensitivity dBm Rx Saturation dBm Distance km b Power Budget dB MM ST 62 5 125 850 16 9 34 11 2 2 18 MM ST 50 125 850 19 8 12 8 34 11 2 2 14 2 a Typical b Typical distance The maximum distance is greatly dependent on factors such as cable type the number of connectors and number of splices Consult a Siemens sales associates when determining maximum distances Fast Ethernet 10 100 Mbps Optical Spec...

Страница 43: ...15 SM LC 9 125 1310 7 3 24 3 25 17 a All cabling is duplex type unless specified otherwise b Typical c All optical power numbers are listed as dBm averages d Typical distance The maximum segment length is greatly dependent on factors such as fiber quality and the number of patches and splices Consult a Siemens sales associates when determining maximum segment distances GBIC Gigabit 1 Gbps Transcei...

Страница 44: ... radius surrounding the center of the enclosure b Operating temperature may vary based on the limitations of installed SFPs Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings c Non condensing 5 8 Mechanical Specifications Weight 5 2 kg 11 5 lbs Ingress Protection IP30 Enclosure 18 AWG Galvanized Steel 5 9 Dimension Drawings Note All dimensions are in millimeters unless oth...

Страница 45: ...Technical Specifications 5 9 Dimension Drawings 285 49 438 15 313 18 44 45 0 8 Figure 5 1 Overall Dimensions 36 RUGGEDCOM RSG2300P Installation Manual 04 2022 C79000 G8976 1047 18 ...

Страница 46: ...ns 5 9 Dimension Drawings 479 29 28 96 51 05 25 40 11 68 32 77 461 0 6 35 31 75 9 9 6 35 470 4 21 08 12 70 313 18 308 35 Figure 5 2 Rack Mount Dimensions RUGGEDCOM RSG2300P Installation Manual 04 2022 C79000 G8976 1047 18 37 ...

Страница 47: ...s 5 9 Dimension Drawings 134 3 51 6 159 8 84 1 285 5 486 4 476 3 38 9 125 5 80 0 11 7 158 0 127 5 7 4 10 4 Figure 5 3 Panel and DIN Rail Mount Dimensions 38 RUGGEDCOM RSG2300P Installation Manual 04 2022 C79000 G8976 1047 18 ...

Страница 48: ...rd with UL 62368 1 UL 62368 1 Information Technology Equipment Safety Part 1 General Requirements The Certificate Body CB test certificate is available on SIOS at https support industry siemens com cs ww en view 109794212 6 1 2 European Union EU This device is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives EN 62368 ...

Страница 49: ...onable protection against harmful interference when the equipment is operated in a commercial environment This device generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which ca...

Страница 50: ...lling Electromagnetic Compatibility Notice 2008 made under Section 182 of the Radiocommunications Act 1992 Radiocommunications Compliance Labelling Electromagnetic Radiation Notice 2003 made under Section 182 of the Radiocommunications Act 1992 Telecommunications Labelling Customer Equipment and Customer Cabling Notice 2001 made under Section 407 of the Telecommunication Act 1997 The device is mar...

Страница 51: ...y for Industrial Environments IEC 61850 3 Communication Networks and Systems in Substations Part 3 General Requirements 6 2 EMC and Environmental Type Tests The RUGGEDCOM RSG2300P has passed the following Electromagnetic Compatibility EMC and environmental tests EMC Type Tests per IEC 61850 3 Test Description Test Levels Severity Levels Enclosure Contact 8 kV IEC 61000 4 2 ESD Enclosure Air 15 kV ...

Страница 52: ...s IEC 61000 4 16 Mains Frequency Voltage AC and DC Power Ports 30 V Continuous 300 V for 1s 4 IEC 61000 4 17 Ripple on DC Power Supply DC Power Ports 15 3 IEC 61000 4 29 Voltage Dips and Interrupts DC Power Ports 30 for 0 1 s 60 for 0 1 s 100 for 0 05 s Signal Ports 2 kV Fail Safe Relay Output DC Power Ports 2 kV Dielectric Strength AC Power Ports 2 kV Signal Ports 5 kV Fail Safe Relay Output DC P...

Страница 53: ...mon 1 kV differential mode 1 MHz Signal Ports 5 kV Fail Safe Relay Output DC Power Ports 5 kV HV Impulse AC Power Ports 5 kV Signal Ports 2 kV DC Power Ports 2 kV Dielectric Strength AC Power Ports 2 kV Damped Oscillatory Magnetic Field Enclosure Ports 100 A m Environmental Type Tests Test Description Test Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test...

Страница 54: ...dustry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario L4K 4E5 Canada 2022 Siemens Canada Ltd Subject to change ...

Отзывы: