Installing the Device
2.3.2 Mounting the Device on a DIN Rail
To secure the device to a standard 48 cm (19 in) rack, do the following:
Note
The device can be ordered with the communication ports located at the front or rear
of the device. Placing the ports at the rear allows all data and power cabling to be
installed and connected at the rear of the rack.
1. Make sure the rack mount adapters are installed on the correct side of the
chassis.
• To make the modules and ports accessible, install the rack mount adapters
at the rear of the chassis
• To make the management ports and LEDs accessible, install the rack mount
adapters at the front of the chassis
Note
The chassis features multiple mounting holes, allowing the rack mount adapters
to be installed up to 25 mm (1 in) from the face of the device.
1
2
3
3
1
Rear
2
Front
3
Rack Mount Adapter
Figure 2.1
Rack Mount Adapters
2. If required, install adapters on the opposite side of the device to protect from
vibrations.
3. Insert the device into the rack.
4. Secure the adapters to the rack using the supplied hardware.
2.3.2
Mounting the Device on a DIN Rail
For DIN rail installations, the RUGGEDCOM RSG2300P can be equipped with panel/
DIN rail adapters pre-installed on each side of the chassis. The adapters allow the
device to be slid onto a standard 35 mm (1.4 in) DIN rail.
NOTICE
DIN rail mounting is not recommended for constant vibration environments.