3 Notes 

 

The local regulations for electrical installations must be 
complied with 

 

If the reference room is equipped with thermostatic radiator 
valves, they must be set to their fully open position 

 

In the event of a power failure at the REV-R.03/1, the relay will 
be deenergized. 

 

If in normal operation REV-R.03/1 does receive for more than  
25 minutes a very weak or no control telegram from 
REV23.03RF, LED_1 starts to flash in red. 
If control telegram is still understood correctly, receiver 

continues with normal operation. If control telegram is not 
understood anymore, relay remains in last position being 
switched to before. 
As soon as REV-R.03/1 does receive any correct control 
telegram from REV23.03RF again, receiver continuous with 
normal operation 

 

In case of error, REV-R.03/1 switches off relay approximately  
60 minutes after reception of last correct control telegram.  
The controlled device is also switched off and LED_1 flashes  
in red. 
As soon as REV-R.03/1 does receive any correct control 
telegram from REV23.03RF again, receiver continuous with 
normal operation 

Commissioning RF Set

Switch on REV23.03RF 

 

Remove the battery transit tab (also refer to Fig. F): As soon 
as the battery transit tab is removed, the unit starts to operate. 

Mount REV-R.03/1 temporarly 

 

If possible, mount receiver temporarly in a first run (e.g. double 
coated tape). Doing that, location of best RF reception can be 
identified later on. 
See clause “5 Find location of best reception“ 

 

Completely wire and mount REV-R.03/1 temporarly. Proceed 
according Fig. H to M (please also close front cover) 

Link REV-R.03/1 with REV23.03RF 

a)  Switch on power at REV-R.03/1: LED_1 (Fig. H) lights always 

in red or flashes in red 

b)  Press the "RESET“ button on REV-R.03/1 for about  

4 seconds: The orange LED_2 (Fig. H) will flash very fast  
and briefly (stored address of REV23.03RF will be erased) 

c) 

Press the "SET“ button (set / learn) for about 3 sec. until the 
orange LED starts flashing slowly and continuously: Receiver  
is now in learning mode 

d)  The receiver stays max. 25 minutes in learning mode. If no 

learning telegram from REV23.03RF is received during that 
period of time, repeat steps b) and c) again 

e)  Press the ESC button 

 

on REV23.03RF for about  

4 seconds. Learning telegram is transmitted 

f) 

If REV-R.03/1 receives learning telegram, the orange LED_2 
flashes fast and briefly 

g)  If the orange LED_2 is steady on, the relay is energized  

(= controlled device ON) 

h)  If the orange LED_2 is dark, the relay is deenergized  

(= controlled device OFF) 

i) 

Depending on the operating state, REV23.03RF repeats the 
ON or OFF control telegram every 3 minutes. With this the 
relay will be switched ON or OFF according to control telegram 
latest after 3 minutes 

j) 

If REV-R.03/1 does not receive any correct control telegram 
within 60 minutes, controlled device is being switched off and 
LED_1 flashes in red 

k) 

In the event of a power failure at the REV-R.03/1, the relay will 
be deenergized. 

4 Site 

REV23.03RF 

 

Site REV23.03RF at preferred location for mounting at wall or 
setting up with stand. Remove the unit from its base by 
proceeding according to Fig. A: 
 - for wall mount, refer to Figs. B, C and D 
 - for set up with stand, refer to Fig. E 

 

Also refer to “Mounting and siting notes REV23.03RF and  
REV-R.03/1“ 

Find location of best RF reception 

a)  Switch off power at REV-R.03/1 
b)  Switch on REV23.03RF, site at prefered location and press 

override button 

 

for about 4 seconds: REV23.03RF 

transmits test telegrams every 2 seconds. Transmission of test 
telegrams stopps automatically after 10 minutes or after 
pressing either “ESC” button or override button 

c) 

Switch on power at REV-R.03/1 

d)  Observe both LEDs on REV-R.03/1 from a distance of  

2…3 meters 

e)  Orange LED_2 must flash briefly every 2 seconds.  

Does LED_2 not flash every 2 seconds, distance between 
REV23.03RF and REV-R.03/1 is too far. Mount REV-R.03/1 
closer to REV23.03RF 

f) 

LED_1 shows received signal strength of last telegram: 

 

LED_1 flashes red: 

Signal is too weak to get a durable 

 

 

durable link. Mount REV-R.03/1  

 

 

closer to REV23.03RF 

 

LED_1 flashes green:  We distinguish between three  

 

 

signal strenghts:  

 

 

Very good (flashes 3x),  

 

 

Good (flashes 2x) and 

 

 

satisfactory (flashes 1x). 

 

 

As soon as LED_1 flashes in green,  

 

 

link between REV23.03RFand  

 

 

REV-R.03/1 is basically ok. 

g)  Move REV-R.03/1 within an area of approximately 1 square 

meter to find location of best RF reception. Always observe 
LEDs from a distance of 2…3 meters.  
To get a durable link, we recommend to site REV-R.03/1 at  
a location where signal strength is at least “Good”. 

Explanation to LED_1 and LED_2 

LED_1 lights always in red: 

 
 
 
 

LED_1 flashes in red: 

 
 
 
 

LED_1 flashes 3 times in green: 

 
 
 
 
 

 
 

LED_1 flashes 2 times in green: 

 
 
 
 
 

 
 

LED_1 flashes 1 time in green: 

 
 
 
 
 
 

Red on 
 
Red off 

No REV23.03RF linked

Red on 
 
Red off

Signal strength too weak

Green on 
 
Green off 

Signal strength: Very good 

1   2   3 

1   2   3 

Starting 
sequence 

Starting 
sequence 

Green on 
 
Green off 

Signal strength: Good 

1   2 

1   2 

Starting 
sequence 

Starting 
sequence 

Starting 
sequence 

Green on 
 
Green off 

Signal strength: Satisfactory 

Starting 
sequence 

Starting 
sequence 

Starting 
sequence 

Содержание REV-R.03/1

Страница 1: ...ung Installation instructions Instructions d installation Istruzioni di montaggio Instrucciones de montaje Montage instructie Návod k montáži a uvední do provozu Instruções de montagem Installationsvejledning Asennusohje Installationsanvisning Οδηγίες εγκατάστασης A B C D E F ...

Страница 2: ...ICK 2 3 CLICK 1 1 2 1 1 3 1 1 3 t T 17 18 19 4 2 2254D01 16 3 1 4h C 1 2h C 1h C P 1 2 1 1 1 Pon 20 C T1 1 h h h TRx h h h h h h h h h 1 1 4 1 1 4 C t 2211Z16 12 min C t 2211Z16 PID 12 6 min C t 2211Z16 PID 6 C t 0 5 C 2211Z16 1 1 5 1 1 6 1 1 6 ...

Страница 3: ...CE1G2265xx 18 11 2005 3 36 H I K L M REV R 03 1 REV R 03 1 LED_1 LED_2 REV R 03 1 ...

Страница 4: ...mme vom REV23 03RF empfängt arbeitet der Empfänger normal weiter Bei Netzunterbruch am REV R 03 1 wird das Relais auf AUS geschaltet Inbetriebsetzung RF Set 1 REV23 03RF einschalten Schwarzen Isolierstreifen entfernen Bild F Sobald der Isolier streifen am Batteriekontakt entfernt wird ist das Gerät in Betrieb 2 REV R 03 1 provisorisch montieren Wenn möglich den Empfänger zuerst provisorisch montie...

Страница 5: ...h Drücken auf den Rollwahlschalter blinkt die aktuell gemessene Temperatur und kann durch Rollen gegen das Display oder vom Display weg um max 2 C neu kalibriert werden Eingabe speichern mit einem Druck auf den Rollwahlschalter siehe auch Abbildung 1 1 2 Sollwert Begrenzung 2 Einstellmöglichkeiten oder In der Fachmannebene kann vom blinkenden CAL Symbol mit einer Rollbewegung gegen das Display auf...

Страница 6: ...te hinter der Nadelöffnung mindestens eine Sekunde drücken Dadurch werden die benutzerspezifischen Einstellungen auf ihre Standardwerte zurückgesetzt die Fachmann Einstellungen bleiben unverändert Die Uhr beginnt bei 12 00 Während der Resetzeit leuchten alle Anzeigefelder des Displays und können so überprüft werden Alle benutzerdefinierten Daten plus Heizfachmann Einstellungen Taste hinter der Nad...

Страница 7: ...h If the orange LED_2 is dark the relay is deenergized controlled device OFF i Depending on the operating state REV23 03RF repeats the ON or OFF control telegram every 3 minutes With this the relay will be switched ON or OFF according to control telegram latest after 3 minutes j If REV R 03 1 does not receive any correct control telegram within 60 minutes controlled device is being switched off an...

Страница 8: ...ture variations 1 1 5 Periodic pump run This function protects the pump against seizing during longer off periods Periodic pump run is activated for a minute every 24 hours at 12 00 when pump run is activated the flame symbol appears on the display On the heating engineer level change from the flashing CAL symbol to the symbol by rolling twice away from the display factory setting periodic pump ru...

Страница 9: ...altérée le relais reste dans la dernière position Dès que le REV R 03 1 reçoit à nouveau des télégrammes corrects du REV23 03RF le récepteur reprend son fonctionnement normal En cas de dysfonctionnement le REV R 03 1 arrête le relais environ 60 minutes après la réception du dernier télégramme de commande correct L appareil commandé est ainsi arrêté et la LED_1 clignote rouge Dès que le REV R 03 1 ...

Страница 10: ...ois vert LED_1 clignote 1 fois vert LED_2 éteinte en permanence LED_2 allumée en permanence LED_2 clignote en permanence LED_2 clignote brièvement réception d un télégramme de commande 7 Terminer le montage du REV R 03 1 a Mettre l appareil hors tension b Marquer l endroit où se trouve le REV R 03 1 c Au besoin défaire le câblage d Monter l appareil à l endroit marqué le câbler complètement et fer...

Страница 11: ...nger il faut modifier la consigne antigel dans le menu de température T voir Mode d emploi 2 Contrôle des fonctions a Vérifier l affichage Si l afficheur reste vide vérifier la mise en place et l état des batteries b Régime Confort c Dans le menu température T régler la consigne de température à 29 C voir mode d emploi d Le relais et par conséquent l organe de réglage doivent commuter voire se met...

Страница 12: ...tore è ora in modalità di apprendimento d Il ricevitore ora è pronto per ricevere il segnale dal regolatore trasmettitore per un tempo max di 25 minuti Se non dovesse ricevere alcun segnale proveniente dal trasmettitore ripetere i punti b e c e Premere il pulsante ESC sul trasmettitore REV23 03RF per 4 secondi il telegramma per il riconoscimento è trasmesso al ricevitore f Quando il ricevitore ric...

Страница 13: ... ottimizzazione vedi fig e Premere il pulsante per entrare nel parametro Il simbolo lampeggia impostazione di fabbrica Premere per confermare o scorrere per cambiare valore 1 o escludere l ottimizzazione Premere di nuovo per confermare l impostazione 1 1 4 Modalità di regolazione PID Nel livello tecnico scorrere verso il basso dal simbolo CAL fino ad arrivare al livello delle modalità di regolazio...

Страница 14: ...ar en que las señales transmitidas y recibidas se distorsionen lo menos posible Por esta razón deberán respetarse los siguientes puntos con los REV23 03RF y REV R 03 1 No montar las unidades sobre superficies metálicas No montar las unidades cerca de cables eléctricos equipos electrónicos tipo PCs televisiones microondas etc No montar las unidades cerca de grandes estructuras de metal u otros elem...

Страница 15: ...EV R 03 1 el relé se desenergiza 4 Ubicación del REV23 03RF Coloque el REV23 03RF en la ubicación preferente para su montaje en pared o erguido libremente con peana Retire la unidad de su base tal como se indica en la Fig A para montaje en pared ver las Figs B C y D para montaje erguido con peana ver la Fig E Ver también Notas de montaje y ubicación de los REV23 03RF y REV R 03 1 5 Encontrar ubica...

Страница 16: ...contra agarrotamiento después de largos periodos de inactividad El funcionamiento periódico de la bomba se activa durante un minuto cada 24 horas a las 12 00 cuando se activa la bomba aparece el símbolo de llama en la pantalla En el programa de instalación cambiar del símbolo parpadeante CAL al símbolo girando el selector hacia abajo dos posiciones desconexión periódica de la bomba Pulsar para ace...

Страница 17: ...tvanger weer normaal verder Bij een fout schakelt de REV R 03 1 het relais ca 60 minuten na het ontvangen van het laatste correcte signaal uit Het aangestuurde apparaat wordt uitgeschakeld en LED_1 knippert rood Zodra de REV R 03 1 weer correcte signalen van de REV23 03RF ontvangt functioneert de ontvanger weer normaal Bij een netspanningsonderbreking aan de REV R 03 1 wordt het relais UIT geschak...

Страница 18: ...n het display en daarna er naar toe wordt het installateursniveau vrijgegeven Zie ook afb G 1 1 1 Opnemer calibreren Na het activeren van het installateursniveau knippert het symbool CAL Door het indrukken van de rolschakelaar knippert de actueel gemeten temperatuur en kan door rollen naar de display of er vanaf max 2 C opnieuw worden gecalibreerd De instelling opslaan met een druk op de rolschake...

Страница 19: ...nste bedrijfswijze kiezen 3 Reset Door de gebruiker gedefinieerde instellingen De toets achter de naaldopening minstens een seconde indrukken daardoor worden de gebruikersspecifieke instellingen teruggezet naar hun standaardwaarden de installateurs instellingen blijven onveranderd De klok begint bij 12 00 Tijdens de resettijd branden alle weergavevelden van de display en kunnen zo worden gecontrol...

Страница 20: ...je sepnuté ovládané zařízení je zapnuté h Pokud oranžová LED_2 nesvítí výstupní relé je rozepnuté ovládané zařízení je vypnuté i V závislosti na provozním režimu opakuje regulátor REV23 03RF vysílání řídicího ZAP nebo VYP telegramu každých 3 minut Díky tomu se výstupní relé sepne nebo rozepne v závislosti na charakteru řídicího telegramu nejpozději do 3ti minut j Pokud REV R 03 1 nezachytí během 6...

Страница 21: ...í 5 29 C Buď potvrďte stiskem tlačítka nebo otáčejte dále Začne blikat symbol nastavení 16 29 C Stiskem tlačítka potvrdíte tuto volbu 1 1 3 Optimalizace času zapnutí vytápění V úrovni odborníka na vytápění je možné otočením rolovacího tlačítka o dva stupně směrem k displeji změnit symbol CAL na symbol optimalizace startu vytápění Viz také obr a 1 1 3 1 1 3 t T 17 18 19 4 2 2254D01 16 3 1 4h C 1 2h...

Страница 22: ...později do jedné minuty se musí sepnout výstupní relé a ovládané zařízení Na displeji se zobrazí symbol V opačném případě Zkontrolujte ovládané zařízení a připojení kabelů Prostorová teplota může být vyšší než 29 C e Žádanou teplotu vraťte zpět na původní hodnotu nastavení z výroby 19 C nebo vlastní nastavení f Vyberte požadovaný druh provozu 3 Funkce reset Reset pouze údajů nastavených uživatelem...

Страница 23: ... 1 LED_1 Fig H permanece vermelho ou pisca em vermelho b Prima o botão RESET no REV R 03 1 por cerca de 4 segundos O LED laranja LED_2 Fig H pisca brevemente muito rapidamente o endereço do REV23 03RF será apagado c Prima o botão SET set learn por cerca de 3 seg até que o LED laranja comece a piscar lentamente O receptor encontrase em modo de aprendizagem d O receptor permanecerá um máximo de 25 m...

Страница 24: ...4 Modo de controlo No nível de engenharia mude do simbolo CAL a piscar para os símbolos dos diversos modos de controlo ver Fig Prima para aceitar parâmetro de fábrica piscará Prima para aceitar ou continue rolando para cima para seleccionar um dos seguintes modos de controlo PID 6 PID 12 ou Prima para aceitar o modo de controlo pretendido Uma descrição dos diversos modos de controlo é dada abaixo ...

Страница 25: ...apparater osv Monter ikke apparaterne i nærheden af større metal konstruktioner eller andre konstruktionselementer med tætmaskede metalgitre såsom specialglas eller specialbeton Afstanden mellem regulator sender og modtager må ikke være større en 20 m eller 2 etager 1 2 REV23 03RF regulator sender REV23 03RF skal helst placeres i hovedopholdsrum met vægmontering i henhold til fig C fri placering i...

Страница 26: ...ker hvert 2 sekund er afstanden mellem REV23 03RF og REV R 03 1 for stor Monter REV R 03 1 tættere på REV23 03RF f LED_1 viser den sidst modtagne signalstyrke LED_1 blinker rødt Signalet er for svagt til at sikre en varig forbindelse Monter REV R 03 1 tættere på REV23 03RF LED_1 blinker grønt Der skelnes mellem tre signalstyrker Meget god 3 god 2 og tilfredsstillende 1 Når LED_1 blinker grønt er f...

Страница 27: ...driftsformvælgeren skiftes til symbolet se også fig Hvis standardværdien på 5 C skal ændres ændres setpunktet for frostbeskyttelse via temperaturmenuen T se betjeningsvejledning 2 Funktionskontrol a Kontroller at der er visning på displayet Er dette ikke tilfældet kontrolleres batteriernes montering og funktion b Driftsform Komfort c Med temperaturmenuen T indstillet setpunktet for temperatur til ...

Страница 28: ...23 03RF stä tee uudelleen vaiheet b ja c e Paina REV23 03RF n ESC painiketta noin 4 sekunnin ajan Oppimissähke lähetetään f Jos REV R 03 1 vastaanottaa oppimissähkeen oranssi LED_2 vilkkuu nopeasti ja lyhyesti g Jos oranssi LED_2 palaa jatkuvasti rele on vetäneenä ohjattu laite päällekytkettynä h Jos oranssi LED_2 ei pala rele on päästäneenä ohjattu laite poiskytkettynä i REV23 03RF toistaa 3 minu...

Страница 29: ...kunkin säätötavan kuvaus katso myös kuva Hankalat säätöjärjestelmät Puhdas kaksipistesäädin kytkentäero 0 5 C tehdasasetus Self learning itseoppiva säätö Sopii kaikkiin sovelluksiin PID 12 Normaalit säätöjärjestelmät Kohteisiin joissa on normaaleja lämpötilanvaihteluita PID 6 Nopeat säätöjärjestelmät Kohteisiin joissa on suuria lämpötilanvaihteluita 1 1 5 Pumpun jaksottaiskäyttö Tämä toiminto suoj...

Страница 30: ...s Om referensrummet är utrustat med termostatventiler skall dessa låsas i helt öppet läge Om REV R 03 1 i normal drift inte erhåller en mycket svag eller ingen styrmeddelande från REV23 03RF under 25 minuter börjar LED_1 att blinka rött Om styrmeddelandet mottagits korrekt fortsätter mottagaren att arbeta normalt Om styrmeddelandet inte mottagits korrekt kvarstår reläet i den senaste valda positio...

Страница 31: ...era platsen där REV R 03 1 befinner sig nu c Om så erfordras lossa den elektriska inkopplingen d Montera mottagaren på den tidigare markerade platsen enligt bild H till M koppla anslutningarna och stäng kapslingen e Koppla på matningsspänningen Konfiguration och funktionskontroll av REV23 03RF 1 Konfiguration 1 1 Tillträde till värmeinstallatörnivå Värmeinstallatörnivån aktiveras genom samtidig in...

Страница 32: ...et standardvärde 19 C eller egen inställning f Välj önskat driftsätt 3 Återställning Användardefinierade data Tryck på knappen bakom nålöppningen i min en sekund Därigenom återställs de användarspecifika inställningarna till standardvärden inställningarna för Värmeinstallatör kvarstår oförändrade Tiden startar kl 12 00 Under återställningstiden lyser samtliga indikeringsfält i displayen och kan då...

Страница 33: ...µένο η ελεγχόµενη συσκευή είναι ανοικτή ON h Εάν το πορτοκαλί LED_2 είναι σκοτεινό το ρελέ είναι απενεργοποιηµένο η ελεγχόµενη συσκευή είναι κλειστή OFF i Αναλόγως της κατάστασης λειτουργίας ο REV23 03RF επαναλαµβάνει τα σήµατα ελέγχου ενεργοποίησης ON ή απενεργοποίησης OFF κάθε 3 λεπτά Έτσι το ρελέ ανοίγει ON ή κλείνει OFF ανάλογα µε το πιο πρόσφατο σήµα ελέγχου του πενταλέπτου j Εάν ο REV R 03 1...

Страница 34: ...λέγχου Οι διάφοροι τρόποι ελέγχου περιγράφονται στη συνέχεια βλέπε επίσης Σχ ύσκολα ελεγχόµενα συστήµατα Ρυθµίστε τις δύο θέσεις on off του ελεγκτή µε διαφορικό διακοπής 0 5 C εργοστασική ρύθµιση Αυτοεκπαίδευση προσαρµόσιµος έλεγχος Κατάλληλος για όλες τις τυποποιηµένες εφαρµογές PID 12 Κανονικά ελεγχόµενα συστήµατα Για θέσεις µε συνήθεις διακυµάνσεις θερµοκρασίας PID 6 Ταχέως ελεγχόµενα συστήµατα...

Страница 35: ... τα πλήκτρα θερµότερου και ψυχρότερου για τουλάχιστον ένα δευτερόλεπτο Μετά την επανεκκίνηση φορτώνονται εκ νέου οι εργοστασιακές ρυθµίσεις ανατρέξτε επίσης στο λήµµα Εργοστασιακές ρυθµίσεις των οδηγιών λειτουργίας 4 Σηµειώσεις Ο ελεγκτής είναι συµβατός µε το πρότυπο λογισµικού Α τάξης Software Class A και προτείνεται για χρήση σε καταστάσεις κανονικής µόλυνσης Ο REV23 03RF SET είναι ένα συγκρότηµ...

Страница 36: ...ajo NA 24 250 V CA 6 2 5 A Maakcontact AC 24 250 V 6 2 5 A Spínací kontakt AC 24 250 V 6 2 5 A Contacto normalmente aberto AC 24 250 V 6 2 5 A L2 Contacto de trabajo NC 24 250 V CA 6 2 5 A Verbreekcontact AC 24 250 V 6 2 5 A Rozpínací kontakt AC 24 250 V 6 2 5 A Contacto normalmente fechado AC 24 250 V 6 2 5 A M1 Bomba circulación Circulatiepomp Oběhové čerpadlo Bomba de circulação de àgua N Neutr...

Отзывы: