19/70
Siemens Building Technologies
Basic Documentation QAA73.110 Room unit
CE1P2284en
HVAC Products
Handling
10.07.2002
2.8 Parameter settings for the OEM
Boiler-specific settings and protective functions for the boiler manufacturer.
Buttons
Explanation
Line
1
P RO G
Press one of the 2 line selection buttons.
This will take you first to the programming level
"Enduser”.
1
2
P RO G
9 s
Press both line selection buttons for at least 9
seconds.
A special display for entering the code will appear.
3
CODE
Press buttons
-
+
and
P R O G
to enter the
required combination of the access code.
If the combination of buttons is correct, you reach
the programming mode ”OEM”.
è
Wrong
code:
If the code has been entered incorrectly, the display
will change to the "Parameter settings for the heating
engineer”.
4
P RO G
Press the line selection buttons to select the required
line.
The parameter list on the next 2 pages contains all
available lines.
100
. . .
199
5
-
+
Press the + or – button to set the required value.
The setting will be stored as soon as you leave the
programming mode or change to another line.
The following parameter list contains all available
lines.
6
You leave the programming level "OEM" by pressing
the Info button.
Continuous
display
If no button is pressed for about 8 minutes, the room unit will automatically return to the
Info level.
Description
Setting
Note