MOBY Commands
4-26
FC 56
J31069-D0155-U001-A0-7618
4.2.13
TRACE
Parameterizing the command in Command_DB
Table 4-21
UDT 50 “MOBY FH CMD” – TRACE
Address
Name
Starting
Value
Commentary
0.0
+0.0
UID
DW#16#0
MDS number, only MOBY U with multitag
+4.0
command
’T’
MDS command: T = Trace (absolute read)
+5.0
sub_command_1
B#16#0
Not used
+6.0
sub_command_2
B#16#0
Not used
+7.0
sub_command_3
B#16#0
Not used
+8.0
Filename
’xxxxxxxx’
Not used
+16.0
length
L#1
Length in bytes of the data to be read
+20.0
address_MDS
W#16#0
Physical start address of the data on the MDS
to be read
+22.0
DAT_DB_number
48
Data DB. The read data are written to this DB.
+24.0
DAT_DB_address
0
Address of the beginning of the user data in
the data DB
+26.0
QUEUE_DB_number
48
Not used
+28.0
QUEUE_DB_address
0
Not used
=30.0
Acknowledgment data in the TRACE command
The user data contained in the acknowledgment of the TRACE command are
written to the address parameterized in the command.
Содержание MOBY FC 56
Страница 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Страница 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Страница 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...