Sample Applications
5-14
FC 56
J31069-D0155-U001-A0-7618
UDT 140: Result of SLG diagnosis III
Table 5-5
UDT 140 “MOBY SLG status diag. 3”
Address
Name
Type
Starting
Value
Commentary
0.0
STRUCT
+0.0
status_info
BYTE
B#16#0
SLG status mode
+1.0
number_MDS
BYTE
B#16#0
Range 1 to 24
+2.0
UID
ARRAY [1...24]
DW#16#0
Identified MDS number
*4.0
DWORD
=98.0
END_STRUCT
UDT 170: Result of ASM/SLG-STATUS (sub_command = 00)
Table 5-6
UDT 170 “MOBY FH-STATUS”
Address
Name
Type
Starting
Value
Commentary
0.0
STRUCT
+0.0
FH_Version
ARRAY [1...8]
’0’
Filehandler
Firmware version
*1.0
CHAR
+8.0
last_FH_command
ARRAY [1...26]
B#16#0
Last command executed by
the filehandler
*1.0
BYTE
+34.0
last_FH_acknowledge
ARRAY [1...26]
B#16#0
Last acknowledgment of
the filehandler
*1.0
BYTE
+60.0
antenna_status
BYTE
B#16#0
SLG connection status:
00 = okay
=62.0
END_STRUCT
Содержание MOBY FC 56
Страница 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Страница 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Страница 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...