MOBY Commands
4-23
FC 56
J31069-D0155-U001-A0-7618
4.2.12
MDS-STATUS
Parameterizing the command in Command_DB
Table 4-18
UDT 50 “MOBY FH CMD” – MDS-STATUS
Address
Name
Starting
Value
Commentary
0.0
+0.0
UID
DW#16#0
MDS number, only MOBY U with multitag
+4.0
command
’F’
MDS command: F = Read MDS Status
+5.0
sub_command_1
B#16#0
Set mode of the MDS-STATUS command.
00H
01H
Fetch the MDS parameters of the MDS’s file structure.
The sub_command_2 and sub_command_3 parameters
do not need to be provided.
Fetch the physical MDS parameters of the MDS (only
MOBY U).
+6.0
sub_command_2
B#16#0
Enter current calendar week.
Value range from 1 to 53 (or 01hex to 35hex)
+7.0
sub_command_3
B#16#0
Enter current year.
Value range from 0 to 99 (or 00hex to 63hex,
example: 01 = 2001)
+8.0
Filename
’xxxxxxxx’
Not used
+16.0
length
L#1
Not used
+20.0
address_MDS
W#16#0
Not used
+22.0
DAT_DB_number
48
Data DB. The status data are written to this
DB.
+24.0
DAT_DB_address
0
Address of the beginning of the user data in
the data DB
+26.0
QUEUE_DB_number
48
Not used
+28.0
QUEUE_DB_address
0
Not used
=30.0
Содержание MOBY FC 56
Страница 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Страница 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Страница 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Страница 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...