171
LOGO! Manual
A5E00067781 01
8.4.3 Enhanced LOGO! Solution
In our enhanced solution the gate will automatically open
again when the safety bar is operated.
x
x
I6
Safety bar
x
Q2
I3
I4
Gate is open
Stop switch
x
I1
Q2
Open start switch
T=
5 s
Q1
Open
T=
5 s
x
Q2
Close
I3
I6
I5
I2
Q1
Safety bar
Gate is closed
Stop switch
Close start
switch
Q3
Flashing
light
T=
2 s
Applications