19.4 Connection diagram for LME73.000... without
actuator SQM4...
Note:
The connection diagram shown is merely an example which must be verified in the individual case
depending on the application!
PME73.840... 1-stage
With/without
pilot
ignition
With/without
valve
proving
Without
actuator
X2-09
SA
-Z
SA
-K
L
SA-
N
L
SA
-R
PE
In
pu
t D
b
r3
fo
r
P
V
O
utp
ut
P
V
71
05
d3
8e
/1
009
Figure 82: Connection diagram for LME73.000... without actuator SQM4...
When using the LME73.000... without actuator according to application
Gas direct
ignition (G), 1-stage, gas direct ignition 1 (G), 1-stage, with valve proving,
wire link
Dbr4 must be fitted to the actuator’s X2-09 as shown above
Parameter P515.01 must be set to 0