background image

5/8

 

 
 
1 4 3  
 
 

0

1

2

Special mode: 

0: normal Mode       

1: simply sewing mode       

2: motor initial angle measurement (Do not remove the belt) 

3: Automatically setting the pulley ratio by the CPU. (synchronizer is necessary 

and the belt not removed) 

1 4 4  

0~31 0 

Feedforward torque of motor:       

0: normal functions       

1-31: feedforward torque level 

1 5 3  

1

100 1 

The proportion coefficient of the pieces counter 

1 5 4  

1

9999 1 

Maximum pieces of the counter 

1 5 5  

0

4 0 

Count mode selection (For Sewing Piece) 

0: The counter is invalid       

1: Count up by pieces. When count over, counter will be auto- reset. 

2: Count down by pieces. When count over, counter will be auto- reset. 

3: Count up by pieces. When count over, motor stops and the counter must be 

reset by the external switch or the P key on the panel. 

4: Count down by pieces. When count over, motor stops and the counter must 

be reset by the external switch or the P key on the panel. 

1 6 1  

0

1

2  

Direction of parameter transfer: 

0: no action    1: from operation panel to controller    2: from controller to 

operation panel. 

1 6 2  

1, 2 

 

Restore factory setting 

1 6 3  

1, 2 

 

Save current parameters as user-defined default parameters. 

1 6 4  

-  

Password 

2 0 3  

5-359 10 

Trimming output start angle TS (down needle position angle as the reference 

point) 

2 0 4  

10-359 120 

Trimming output end angle TE (Down needle position angle is the reference 

and this value should be bigger than TS) 

2 0 A  

10-60 20 

Motor torque improvement coefficient during trimming 

2 1 1  

5-359 25 

Thread release output start angle LS (down needle position angle as the 

reference point) 

2 1 2  

10-359 350 

Thread release output end angle LE (Down needle position angle is the 

reference and this value should be bigger than LS) 

2 1 3  

1-999 1 

Thread release output start delay time T1 (ms) 

2 1 4  

1

999 10 

Thread release output end delay time T2 (ms) after up needle position 

2 1 5  

0

1 1 

Wiper function   0: disable    1: enable 

2 1 6  

1

999 10 

Wiper output delay time (ms) 

2 1 7  

1

9999 70 

Wiper output time (ms) 

2 1 9  

0

1 0 

Thread clamp function  0: disable   1: enable 

2 1 A  

10-359 120 

Thread clamp start angle 

2 1 B  

11-359 318 

Thread clamp end angle 

2 2 0  

200

360 360 

Stop position after trimming (motor can stop with a reverse angle) 

2 3 1  

0

1 0 

Auto test mode:    0: stitches mode     1: time mode 

Содержание HMI-15

Страница 1: ... use the controller For installing and operating the controller properly and safely qualified personnel are required Please try to stay away from arc welding equipment in order to avoid electromagnetic interference and malfunction of the controller Keep in room bellow 45 and above 0 Do not humidity below 30 or above 95 or dew and mist of places Install the control box and other components turn off...

Страница 2: ... Icon Description Index Icon Description Automatic trimming four constant stitch sewing Presser foot lifting after trimming One shot sewing Presser foot lifting at seam end Position up Start back tacking Soft start End back tacking Thread clamp W sewing Number display Free sewing Sewing segments index Multi section constant stitch sewing 2 2 Key Functions Key Name Description Parameter setting key...

Страница 3: ...ycle only lifting at machine stop only lifting at machine stop and after trimming cycle both Trimming cycle selection Enable or disable the trimming cycle Start back tacking setting key Switch during all start tacking type when pressing No tacking once tacking double tacking 4 repeat tacking Tacking stitches A B can be set using the key and the key End back tacking setting key Switch during all en...

Страница 4: ... 70 20 Stitch balance for start back tacking No 1 1 1 5 1 70 24 Stitch balance for end back tacking No 3 1 1 6 1 70 20 Stitch balance for end back tacking No 4 1 3 0 0 1 2 3 2 Speed curve adjustments 0 ramp curve 1 polygonal curve 2 quadric curve 3 S type curve 1 3 1 200 4000 3000 The turning point speed of two segment curve 1 3 2 0 1024 800 The turning point sampling voltage of the pedal when two...

Страница 5: ...operation panel 1 6 2 1 2 Restore factory setting 1 6 3 1 2 Save current parameters as user defined default parameters 1 6 4 Password 2 0 3 5 359 10 Trimming output start angle TS down needle position angle as the reference point 2 0 4 10 359 120 Trimming output end angle TE Down needle position angle is the reference and this value should be bigger than TS 2 0 A 10 60 20 Motor torque improvement ...

Страница 6: ...shown at the same time 3 Press key then return to normal sewing mode No Description No Description 0 1 0 Counter for stitches 0 2 4 Machine angle 0 1 1 Counter for sewing pieces 0 2 5 The sampling voltage of pedal 0 1 3 State of encoder 0 2 6 The ratio between motor and machine 0 2 0 DC voltage 0 2 7 The total used time hours of motor 0 2 1 Machine speed 0 2 8 The sampling voltage of interaction 0...

Страница 7: ...t in the sewing machine Replace encoder Replace sewing motor E r 0 9 Brake circuit failure Check the brake resistor plug on the electric board Replace the control box E r 1 0 Communication failure Check the connection and if necessary plug in Replace the control box E r 11 Machine head needle positioning failure Check if the connection line between machine head synchronizer and controller is loose...

Страница 8: ...actory Setting is recovered displaying as left LCD 3 8888 When the LCD is displayed as 8888888 the recovery is accomplished The machine is recovered back to the initial state in delivery 4 3 Pedal Sensitivity Adjustment Pedal starts moving from the initial position p 136 where the motor stops slowing forward to the low speed point p 137 where the motor run as the minimum speed p 100 continuing to ...

Отзывы: