background image

8/8

 

P 0 2 4 

 

 

 

 

 0 0 0 0

The control system in the restoration of the factory, can be reset up needle 

stop position. 

Step 1: Press 

P

  key, then Press

 

  ,enter the monitor mode. Parameter 

024 is shown, which means the default up needle stop position in angle

(

).

 

 0 1 2 4

 

Step 2: Turn the hand wheel and adjust to the right position as up needle stop, 

and the needle position angle is shown simultaneously.

 

 

 0 0 0 0

Step 3: Long press 

P

+

key, the new up needle position is preserved and the 

parameter is set to zero.Press 

key to exit. 

4.2 The Recovery of Default Factory Setting 

P 0 2 4 

 

Step 1: Press 

P

key, then 

press

 

  enter the monitor mode. 

- - - - 

 

Step 2: Press key 

 

for about 5 seconds, then Default Factory Setting is 

recovered displaying as left LCD. 

 8 8 8 8 

 

When the LCD is displayed as 8888888, the recovery is accomplished. The 

machine is recovered back to the initial state in delivery. 

  4.3 Pedal Sensitivity Adjustment 

Pedal starts moving from the initial position (p.136) where the motor stops, slowing forward to the low speed 

point (p.137) where the motor run as the minimum speed (p.100), continuing to the accelerated point (p.138) where 

the motor start to speed up, until the max speed point (p.139) where the motor run up to the maximum speed 

(p.101). And when the pedal steps back to the foot lifter position (p.135), the presser foot lift. Continuing back to the 

auto trimming position (p.134), the line is cut. Adjusting the corresponding parameters, user can acquire the proper 

pedal response to fit the personal habit. 

 

 

 

 

 

 

 

 

Fig. 4-1 pedal movement of each position parameter 

 386P0255A 

                                                                   

2015-11-02 

 

 

 

Содержание HMI-15

Страница 1: ... use the controller For installing and operating the controller properly and safely qualified personnel are required Please try to stay away from arc welding equipment in order to avoid electromagnetic interference and malfunction of the controller Keep in room bellow 45 and above 0 Do not humidity below 30 or above 95 or dew and mist of places Install the control box and other components turn off...

Страница 2: ... Icon Description Index Icon Description Automatic trimming four constant stitch sewing Presser foot lifting after trimming One shot sewing Presser foot lifting at seam end Position up Start back tacking Soft start End back tacking Thread clamp W sewing Number display Free sewing Sewing segments index Multi section constant stitch sewing 2 2 Key Functions Key Name Description Parameter setting key...

Страница 3: ...ycle only lifting at machine stop only lifting at machine stop and after trimming cycle both Trimming cycle selection Enable or disable the trimming cycle Start back tacking setting key Switch during all start tacking type when pressing No tacking once tacking double tacking 4 repeat tacking Tacking stitches A B can be set using the key and the key End back tacking setting key Switch during all en...

Страница 4: ... 70 20 Stitch balance for start back tacking No 1 1 1 5 1 70 24 Stitch balance for end back tacking No 3 1 1 6 1 70 20 Stitch balance for end back tacking No 4 1 3 0 0 1 2 3 2 Speed curve adjustments 0 ramp curve 1 polygonal curve 2 quadric curve 3 S type curve 1 3 1 200 4000 3000 The turning point speed of two segment curve 1 3 2 0 1024 800 The turning point sampling voltage of the pedal when two...

Страница 5: ...operation panel 1 6 2 1 2 Restore factory setting 1 6 3 1 2 Save current parameters as user defined default parameters 1 6 4 Password 2 0 3 5 359 10 Trimming output start angle TS down needle position angle as the reference point 2 0 4 10 359 120 Trimming output end angle TE Down needle position angle is the reference and this value should be bigger than TS 2 0 A 10 60 20 Motor torque improvement ...

Страница 6: ...shown at the same time 3 Press key then return to normal sewing mode No Description No Description 0 1 0 Counter for stitches 0 2 4 Machine angle 0 1 1 Counter for sewing pieces 0 2 5 The sampling voltage of pedal 0 1 3 State of encoder 0 2 6 The ratio between motor and machine 0 2 0 DC voltage 0 2 7 The total used time hours of motor 0 2 1 Machine speed 0 2 8 The sampling voltage of interaction 0...

Страница 7: ...t in the sewing machine Replace encoder Replace sewing motor E r 0 9 Brake circuit failure Check the brake resistor plug on the electric board Replace the control box E r 1 0 Communication failure Check the connection and if necessary plug in Replace the control box E r 11 Machine head needle positioning failure Check if the connection line between machine head synchronizer and controller is loose...

Страница 8: ...actory Setting is recovered displaying as left LCD 3 8888 When the LCD is displayed as 8888888 the recovery is accomplished The machine is recovered back to the initial state in delivery 4 3 Pedal Sensitivity Adjustment Pedal starts moving from the initial position p 136 where the motor stops slowing forward to the low speed point p 137 where the motor run as the minimum speed p 100 continuing to ...