Siemens HMI-15 Скачать руководство пользователя страница 2

2/8

 

 
1.3 Wiring and Grounding

 

We must prepare the system grounding project, please a qualified electrical engineer to be construction. 

Product is energized and ready for use; you must ensure that the power outlet the AC input is securely grounded. 

The grounding wire is yellow and green lines, it must be connected to the grid and reliable security protection on the 

ground to ensure safe use, and prevent abnormal situation. 

All power lines, signal lines, ground lines, wiring not to be pressed into other objects or excessive distortion, 

to ensure safe use! 

 
2 Operation Panel Instructions 

2.1  Operation Panel Display Instruction         

 

 

 

 

 

 

 

Fig.2-1H-15 Operation Panel

                                                                           

 Fig.2-2 LCD Display

 

Index 

Icon Description Index

Icon 

Description 

① 

 

Automatic trimming

 

⑨ 

 

four-constant-stitch sewing

 

② 

 

Presser foot lifting after trimming

⑩ 

 

One-shot sewing

 

③ 

 

Presser foot lifting at seam end 

 

 

Position up

 

④ 

 

Start back tacking 

 

 

Soft start

 

⑤ 

 

End back tacking 

 

 

Thread clamp

 

⑥ 

 

W

 sewing

 

 

 

Number display

 

⑦ 

 

Free sewing

 

 

 

Sewing segments index

 

⑧ 

 

Multi-section constant-stitch 

sewing

 

 

 

 

 

2.2 Key Functions 

Key Name 

Description 

 

Parameter 

setting key

 

Use the key to switch to the program mode. 

The key is parameters confirm key, and back to the previous menu until the operator sewing mode 

state. In addition, work with other key to set a higher level of the parameter. 

 

modification  

setting key 

Parameter to modify the confirmation key, press the 

  again to return to the standby interface. 

 

W sewing

 

The system enter to W sewing mode when press the

  key is lit. Show 

 is 

w sewing interface,default range 1~F corresponds to the 1~15 pin.

 

Содержание HMI-15

Страница 1: ... use the controller For installing and operating the controller properly and safely qualified personnel are required Please try to stay away from arc welding equipment in order to avoid electromagnetic interference and malfunction of the controller Keep in room bellow 45 and above 0 Do not humidity below 30 or above 95 or dew and mist of places Install the control box and other components turn off...

Страница 2: ... Icon Description Index Icon Description Automatic trimming four constant stitch sewing Presser foot lifting after trimming One shot sewing Presser foot lifting at seam end Position up Start back tacking Soft start End back tacking Thread clamp W sewing Number display Free sewing Sewing segments index Multi section constant stitch sewing 2 2 Key Functions Key Name Description Parameter setting key...

Страница 3: ...ycle only lifting at machine stop only lifting at machine stop and after trimming cycle both Trimming cycle selection Enable or disable the trimming cycle Start back tacking setting key Switch during all start tacking type when pressing No tacking once tacking double tacking 4 repeat tacking Tacking stitches A B can be set using the key and the key End back tacking setting key Switch during all en...

Страница 4: ... 70 20 Stitch balance for start back tacking No 1 1 1 5 1 70 24 Stitch balance for end back tacking No 3 1 1 6 1 70 20 Stitch balance for end back tacking No 4 1 3 0 0 1 2 3 2 Speed curve adjustments 0 ramp curve 1 polygonal curve 2 quadric curve 3 S type curve 1 3 1 200 4000 3000 The turning point speed of two segment curve 1 3 2 0 1024 800 The turning point sampling voltage of the pedal when two...

Страница 5: ...operation panel 1 6 2 1 2 Restore factory setting 1 6 3 1 2 Save current parameters as user defined default parameters 1 6 4 Password 2 0 3 5 359 10 Trimming output start angle TS down needle position angle as the reference point 2 0 4 10 359 120 Trimming output end angle TE Down needle position angle is the reference and this value should be bigger than TS 2 0 A 10 60 20 Motor torque improvement ...

Страница 6: ...shown at the same time 3 Press key then return to normal sewing mode No Description No Description 0 1 0 Counter for stitches 0 2 4 Machine angle 0 1 1 Counter for sewing pieces 0 2 5 The sampling voltage of pedal 0 1 3 State of encoder 0 2 6 The ratio between motor and machine 0 2 0 DC voltage 0 2 7 The total used time hours of motor 0 2 1 Machine speed 0 2 8 The sampling voltage of interaction 0...

Страница 7: ...t in the sewing machine Replace encoder Replace sewing motor E r 0 9 Brake circuit failure Check the brake resistor plug on the electric board Replace the control box E r 1 0 Communication failure Check the connection and if necessary plug in Replace the control box E r 11 Machine head needle positioning failure Check if the connection line between machine head synchronizer and controller is loose...

Страница 8: ...actory Setting is recovered displaying as left LCD 3 8888 When the LCD is displayed as 8888888 the recovery is accomplished The machine is recovered back to the initial state in delivery 4 3 Pedal Sensitivity Adjustment Pedal starts moving from the initial position p 136 where the motor stops slowing forward to the low speed point p 137 where the motor run as the minimum speed p 100 continuing to ...

Отзывы: