11.1 Overview
You can load and test your user program using the online functions of
the STEP 5 software.
To use these functions, the CPU must be connected to the PG. The
following interfaces are available for this link:
••
link via the serial standard interface "PG - PLC",
••
link via the 2nd serial interface of the CPU 948,
••
link via the S5 bus with SINEC H1.
The PG functions can operate simultaneously on the two serial
interfaces, however, via the SINEC H1 link, the PG functions can only
be used alternately with those on the serial interfaces
PG functions provide the following support for installing and testing
your STEP 5 program:
Function
Section
Info
Size of the internal RAM and free
user memory
"Memory configuration"
List of loaded blocks
"Output DIR"
Display contents of memory
words/bytes and I/O bytes
"Output address"
Memory management
Delete the whole memory
"Overall reset"
Create more memory space
"Compress memory
Manage blocks
"Transfer/delete blocks"
Program test
Start/stop CPU
"Start/stop"
Test the operation sequence in a
block
"Status block"
Test single program steps
"Program test"
Display signal state of process
variables
"Status variables"
Output signals in the stop mode
"Force"
Display/change process variables
"Force variables"
Table 11-1
Functions for installation and testing
Overview
CPU 948 Programming Guide
11 - 4
C79000-G8576-C848-04
Содержание CPU 948
Страница 10: ...Contents CPU 948 Programming Guide 1 2 C79000 G8576 C848 04 ...
Страница 32: ...Contents CPU 948 Programming Guide 2 2 C79000 G8576 C848 04 ...
Страница 72: ...Data Blocks CPU 948 Programming Guide 2 42 C79000 G8576 C848 04 ...
Страница 74: ...Contents CPU 948 Programming Guide 3 2 C79000 G8576 C848 04 ...
Страница 154: ...Contents CPU 948 Programming Guide 4 2 C79000 G8576 C848 04 ...
Страница 200: ...Contents CPU 948 Programming Guide 5 2 C79000 G8576 C848 04 ...
Страница 308: ...Contents CPU 948 Programming Guide 7 2 C79000 G8576 C848 04 ...
Страница 324: ...Examples of Parameter Assignment CPU 948 Programming Guide 7 18 C79000 G8576 C848 04 ...
Страница 326: ...Contents CPU 948 Programming Guide 8 2 C79000 G8576 C848 04 ...
Страница 370: ...Addressable System Data Area CPU 948 Programming Guide 8 46 C79000 G8576 C848 04 ...
Страница 372: ...Contents CPU 948 Programming Guide 9 2 C79000 G8576 C848 04 ...
Страница 404: ...Operations with the Base Address Register BR Register CPU 948 Programming Guide 9 34 C79000 G8576 C848 04 ...
Страница 486: ...Contents CPU 948 Programming Guide 11 2 C79000 G8576 C848 04 ...
Страница 522: ...PG Functions via the S5 Bus CPU 948 Programming Guide 11 38 C79000 G8576 C848 04 ...
Страница 524: ...Contents CPU 948 Programming Guide 12 2 C79000 G8576 C848 04 ...
Страница 538: ...Contents CPU 948 Programming Guide 13 2 C79000 G8576 C848 04 ...
Страница 546: ...List of Key Words CPU 948 Programming Guide Index 6 C79000 G8576 C848 04 ...