![Siemens Add 7 AddFEM Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/siemens/add-7-addfem/add-7-addfem_manual_377066054.webp)
AddFEM
Technical Data
4-3
AddFEM
C79000–G8076–C900–03
PROFIBUS DP Interfaces
Number of interfaces
2
Baud rate
9.6 Kbauds to 12 Mbauds
Max. line length of a bus segment with both
ends terminated
100 m
Permissible load of the 5–V bus supply to con-
nect further loads without own supply
Max. 80 mA per interface
For detailed information on the PROFIBUS please refer to SIMATIC NET, Manual for
PROFIBUS Networks, Order No. 6GK1970–5CA20–0AA0!
Cycle Times Input/Output (PROFIBUS and Connector X4 – X7)
Analog signal detection
666.667
µ
s
Analog signal output
666.667
µ
s
Digital signal detection
1)
666.667
µ
s
Digital signal output
666.667
µ
s
Counting pulse input
2 ms
1)
Update every 666.667
µ
s
. Due to signal filtering there is an additional dead
time of 666.667
µ
s
between the detection and passing on.