Manual 7XV5655-0BB00
C53000-G1176-C175-3
Page 56 of 79
SIEMENS AG
Overview of Registers
The modem has internal registers, enabling you to modify its configuration
(see also ATS command).
Register
Definition
Default
Options
S0
Auto answer
0
[0..9] rings
S1
Number of rings
0
Read only
S2
Escape character
+
ASCII
S3 CR
character
0x0d
ASCII
S4 LF
character
0x0a
ASCII
S5
BS character
0x08
ASCII
S30
Inactivity timer
0
[0..255] s
(from device software 14.x on)
S31
Baud rate
3
1=2400 2=4800 3=9600 4=19200
5=38400 6=57600 7=115200
S32
Parity
0
0=None 1=Even 2=Odd 3=Mark
4=Space
S33
Data bits
8
7=7 8=8
S34
Stop bits
1
1=1 2=2
S35
RxD timeout
100
[5..255] ms
S36
Char timeout
10
[5..255] ms 0=Off
S37
Bit options
5
[0..255] decimal value
S38 Use
TC57
0
[0..1]
S39 TC57
type
1
[0..3]
S40
Fixed frame length
2
[2..255]
S41
User data length
2
[2..14]
S81 Password
protection 0
[0..1]
S82
Password blocking time
3
[0..255] minutes 0=Off
S83
Wrong password entry
0
[0..255] in the RAM only
S99 *
Time between two rings
4
[0..255] s
S100 Own
IP
10.10.5.1
xxx.xxx.xxx.xxx
S101 Default
gateway
0.0.0.0
xxx.xxx.xxx.xxx
S102 Auto
remote
0.0.0.0
xxx.xxx.xxx.xxx
S103 Subnet
mask
255.255.255.0 xxx.xxx.xxx.xxx
S104 MAC
address
00:09:8E:x:x:x Read
only
S110 *
Valid IP address
0.0.0.0
xxx.xxx.xxx.xxx
S111 *
Valid IP address
0.0.0.0
xxx.xxx.xxx.xxx
S112 *
Valid IP address
0.0.0.0
xxx.xxx.xxx.xxx
S113 *
Valid IP address
0.0.0.0
xxx.xxx.xxx.xxx
S114 *
Valid IP address
0.0.0.0
xxx.xxx.xxx.xxx
S115 *
Valid IP address
0.0.0.0
xxx.xxx.xxx.xxx
S116 *
Valid IP address
0.0.0.0
xxx.xxx.xxx.xxx
S117 *
Valid IP address
0.0.0.0
xxx.xxx.xxx.xxx
S118 *
Valid IP address
0.0.0.0
xxx.xxx.xxx.xxx
S119 *
Valid IP address
0.0.0.0
xxx.xxx.xxx.xxx
* Registers are not output with AT&V