3ZX1012-0VL40-2LA1                                                                                       8 / 10 
4NEB 1795894-10 DS 02 

OFF / 0 

ON / I 

ON /  I 

OFF / 0 

TEST 

1X

 

OK 

OFF

 

OFF             ON 

1X 

OK 

OFF 

 OFF 

9-c 

1X 

OK 

OFF             ON 

OFF 

9-d 

9-e 

9-a 

5X 

OK 

ON 

OFF             ON 

5X 

OK 

OFF            ON 

ON

 

                        

9-b 

4 Nm 

*) 

*) 

*) 

DE 

Der Testablauf darf nur bei geöffneten 

Strombahnen durchgeführt werden

 

EN 

The test sequence may only be performed 

when conducting paths are open 

FR 

La séquence d'essai ne doit être exécutée que 

lorsque les circuits sont ouverts. 

ES 

La secuencia de test sólo debe ejecutarse 

estando abiertos los circuitos de contactos 

IT 

La sequenza di test deve essere eseguita solo 

quando le vie di corrente sono aperte. 

PT 

O processo de teste só pode ser efectuado 

com as calhas de corrente abertas. 

TR 

Test prosedürü sadece akım yolları açık 

vaziyetteyken gerçekleştirilebilir

 

РУ

 

Тест проводить только при открытых  

токопроводах 

 

中文

 

只允许在打开电流路径时执行测试流程

 

 

Содержание 3VL9400-8LC00

Страница 1: ...areil VORSICHT CAUTION PRUDENCE Eine sichere Gerätefunktion ist nur mit zertifizierten Komponenten gewährleistet Reliable functioning of the equipment is only ensured with certified components GEFAHR DANGER DANGER La sécurité de fonctionnement de l appareil n est garantie qu avec des composants certifiés Español Italiano Português Leer y comprender este instructivo antes de la instalación operació...

Страница 2: ...S Alcance del suministro IT Volume di fornitura PT Âmbito do fornecimento TR Teslimat kapsamı TR Teslimat kapsamı 中文 供货范围 3ZX1012 0VL40 2LA1 2 10 4NEB 1795894 10 DS 02 3ZX1012 0VL50 1MA1 Ø 7 1 mm Ø 25 mm Ø 9 mm 13 mm 6 mm cal ISO 6789 3VL94008LC00 a a b b 2X M8 X 16 mm 3VL94008LD00 2X M8 X 16 mm a a b b c e d d e c 3VL9400 3M_00 XXX Jan 7 2002 7 1 2002 XXX Jan 7 2002 7 1 2002 77 0072002 1J 0027 77...

Страница 3: ...3 10 3ZX1012 0VL40 2LA1 4NEB 1795894 10 DS 02 1 2 4 0 Nm M6 X 1 X 100mm 3VL94008LC00 b a b a 1 3VL94008LD00 b a b a 2a OK 2b 2c 2 c 3 0 5 Nm e d 1 ...

Страница 4: ...ZX1012 0VL40 2LA1 4 10 4NEB 1795894 10 DS 02 3VL9400 8LC00 3VL4 407 5 247 5 A 3VL4 3VL4 407 5 247 5 375 5 215 5 A B 3VL4 3VL9400 8LC00 3VL94008LC00 Supplied by Customer Supplied by Customer 3 6 mm 3 6 mm ...

Страница 5: ...5 10 3ZX1012 0VL40 2LA1 4NEB 1795894 10 DS 02 6 3VL9400 8LD00 3VL4 449 289 A 3VL4 3VL9400 8LD00 3VL4 449 289 246 86 A B 3VL4 3VL94008LD00 Supplied by Customer Supplied by Customer 3 6 mm 3 6 mm ...

Страница 6: ...3ZX1012 0VL40 2LA1 6 10 4NEB 1795894 10 DS 02 3c 3a 3 0 Nm 3b 4 3 2 1 3d 1 2 1 0 06 Nm 3 2 1 6 mm 0 2 Nm 3e ...

Страница 7: ...7 10 3ZX1012 0VL40 2LA1 4NEB 1795894 10 DS 02 3VL94008LD00 1 2 Nm 6a X 0 5 ON 1 OFF 0 6b 1 X 25 N ON I OFF 0 2 X 0 X 0 2 1 3VL94008LD00 1 2 Nm 4 ON 1 OFF 0 1 2 ...

Страница 8: ...n conducting paths are open FR La séquence d essai ne doit être exécutée que lorsque les circuits sont ouverts ES La secuencia de test sólo debe ejecutarse estando abiertos los circuitos de contactos IT La sequenza di test deve essere eseguita solo quando le vie di corrente sono aperte PT O processo de teste só pode ser efectuado com as calhas de corrente abertas TR Test prosedürü sadece akım yoll...

Страница 9: ...OK Step 16 10 TEST T OK Step 12 11 TEST T 13 12 a 5 X TOTAL MAX OFF 0 OFF 0 a 1 X 360 9 10 3ZX1012 0VL40 2LA1 4NEB 1795894 10 DS 02 ...

Страница 10: ...en Subject to change without prior notice Bestell Nr Order No 3ZX1012 0VL40 2LA1 4NEB 1795894 10 DS 02 Siemens AG 2004 14 15 Step 9 OK Step 16 TEST T 16 4 Nm 4 Nm Technical Support Internet http www siemens com lowvoltage technical support ...

Отзывы: