relubrication. This is indicated by the fact that during relubrication, oil or grease escapes at the
bearing cover.
● To remove the spent grease, loosen the outer bearing cap.
NOTICE
Removing spent grease
If the spent grease is not removed, then the roller bearings become too hot and can seize
up as the grease distribution mechanism is disturbed.
WARNING
Working on the locating bearing
If the motor is in a vertical position, the rotor can fall out while work is being performed on
the locating bearing. This can result in death, serious injury or material damage.
Support or reduce the load on the rotor when carrying out work with the machine in a
vertical position.
9.3.8
Cleaning cooling air ducts and passages
The cooling ducts must be free of any pollution in order that the machine is adequately cooled.
● Regularly clean the grids, ducts, ribs, pipes etc. to remove dust and pollution.
● Regularly clean the cooling air passages through which the ambient air flows, e.g. using
dry compressed air.
NOTICE
Motor overheating caused by dirt
The frequency of the cleaning intervals depends on the local degree of fouling. The
machine will overheat if the cooling air ducts are polluted and the cooling air cannot flow
without obstruction.
● Regularly check for dirt.
● Clean the cooling air ducts through which the ambient air flows.
9.3.9
Maintaining the anti-condensation heating
The anti-condensation heating is maintenance-free. If it is defective, it can be replaced. In this
case, please contact the Service Center (Page 111).
Maintenance
9.3 Inspection and maintenance
SIMOTICS HV C 1NB1402-2AA84-4CA0-Z
92
Operating Instructions 06/2018
Содержание 1NB1402-2AA84-4CA0-Z
Страница 2: ...26 06 2018 15 34 V3 00 ...
Страница 10: ...Table of contents SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 10 Operating Instructions 06 2018 ...
Страница 22: ...Description SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 22 Operating Instructions 06 2018 ...
Страница 84: ...Operation 8 9 Faults SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 84 Operating Instructions 06 2018 ...
Страница 110: ...Disposal 11 4 Disposal of components SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 110 Operating Instructions 06 2018 ...
Страница 112: ...Service and Support SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 112 Operating Instructions 06 2018 ...
Страница 117: ...117 ...
Страница 118: ...118 ...
Страница 119: ...119 ...
Страница 120: ...120 ...
Страница 121: ...121 ...
Страница 122: ...122 ...
Страница 123: ...123 ...
Страница 124: ...124 ...
Страница 125: ...125 ...
Страница 126: ...126 ...
Страница 127: ...127 ...
Страница 128: ...128 ...
Страница 129: ...129 ...
Страница 130: ...130 ...
Страница 131: ...C 2 Declaration of conformity SIMOTICS HV C 1NB1402 2AA84 4CA0 Z Operating Instructions 06 2018 131 ...
Страница 132: ...Quality documents C 2 Declaration of conformity SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 132 Operating Instructions 06 2018 ...
Страница 133: ...133 ...
Страница 148: ...148 ...
Страница 150: ...Additional documents SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 150 Operating Instructions 06 2018 ...
Страница 154: ...Index SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 154 Operating Instructions 06 2018 ...
Страница 155: ...AF Einbauerklärung Loher LDX U157 AJ EC Declaration of Conformity U161 ...