Motor Description
1.7 Cooling
Forced ventilation, SH 132
Air flow direction from DE to NDE
profile using a mounted radial
fan.
The air is blown through the enclosure corners of the extruded
Connection:
via terminal box
Supply voltage:
3-ph. 400/480 V AC, 50/60 Hz
Maximum current:
0.4 A
Forced ventilation, SH 160
Air flow direction from DE to NDE
rofile using a mounted radial
fan.
The air is blow through the enclosure corners of the extruded p
Connection:
via terminal box
Supply voltage:
3-ph. 400/480 V AC, 50/60 Hz
Maximum current:
0.8 A
Minimum clearance between parts and components mounted by the customer and the air discharge
opening
The following minimum clearance must be maintained between parts and components
mounted by the customer and the air discharge opening:
Table 1-8
Minimum clearance to parts and components mounted by the customer
Shaft height [mm]
Minimum clearance [mm]
80
20
100
30
132
60
160
80
1FT6 synchronous motors
1-22
Configuration Manual, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0