Motor Components (Options)
4.4 Motors without DRIVE-CLiQ
4.4
Motors without DRIVE-CLiQ
Features
4.4.1
Incremental encoders
Function:
•
Angular measuring system for commutation
•
Speed actual value sensing
•
Indirect incremental measuring system for the position control loop
•
One zero pulse (reference mark) per revolution
Table 4-4
Technical data, incremental encoders sin/cos 1Vpp
Incremental encoders
sin/cos 1 Vpp (I–2048)
Incremental encoders
sin/cos 1 Vpp (low SH)
(I–2048)
Mech. limiting speed
15000 RPM
12000 RPM
Operating voltage
5V ± 5%
5V ± 5%
Current consumption
max. 150 mA
max. 150 mA
Resolution, incremental
2048
2048
Incremental signals
1 Vpp
1 Vpp
Angular error
± 40"
± 80"
C–D track (rotor position)
available
available
rHOsrHO
rHO
rHO
rPHFK
rHO rPHFK
8>9@
8>9@
$
%
5
&
'
5
́
́
́
́
́
́
Figure 4-2
Signal sequence and assignment for a positive direction of rotation
1FT6 synchronous motors
Configuration Manual, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0
4-5