Electrical Connections
2.2 Power connection
2.2.3
Connection through a terminal box
•
The terminal assignment in the terminal box must be implemented according to the
diagram.
•
The protective conductor must be connected.
•
Cable lugs acc. to DIN 46234 must be used.
•
Connect-up an optional brake (refer to the diagram).
Notice
Motors with a rated power of more than 100 kW must be grounded using the additional
M12 grounding stud provided at the NDE bearing endshield.
Figure 2-3
Terminal assignment in the terminal boxes
1FT6 synchronous motors
Configuration Manual, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0
2-3