ENGLISH
Siemens AG
610.43 410.21
25
8
Inspection, Maintenance, Disposal
Clean wherever and whenever the degree of contamination makes it necessary in order to
ensure that the waste heat is adequately dissipated.
As the operating conditions vary greatly, one can only cite general intervals for fault-free
operation.
Guidelines:
- Bearing service life 20 000 hours
- Radial shaft seals ca. 5 000 hours with oil lubrication.
When replacing the motor bearings because they have worn, encoders with intrinsic
bearings must also be replaced.
Dispose of the motor in accordance with the national and local regulations in the standard
recycling process or return it to the manufacturer.
Dispose of the encoder electronics properly as electronic scrap.
NOTICE
The encoder system must be readjusted each time after the motor has been
disassembled.