Original operating instructions
MSA400
03.2015
15
Function Teaching-in close without locking
1. Open sliding sash completely (OPEN position).
2. Press the
Prog
button; the LED flashes green.
3. Press and hold the operating push button for approx. 5 seconds until a short acoustic signal sounds 2 times in succession.
4. Release the operating push button.
5. Press and hold button
1
on the remote control until a short acoustic signal sounds.
6. Release button 1, the function has been taught-in. The sliding sash can now be closed without locking it.
Deactivating the close without locking function
1. Open sliding sash completely (OPEN position).
2. Press the
Prog
button; the LED flashes green.
3. Press and hold the operating push button for approx. 5 seconds until a short acoustic signal sounds 2 times in succession.
4. Release the operating push button.
5. Press and hold button
1
on the remote control until a long acoustic signal sounds.
6. Release button
1
, the function has been deactivated.
1.
2.
3.
5.
ca. 5 Sek.
BEEP
1x
BEEP
1x
BEEP
2x
Reset the sash position
Perform reference run
1. The sliding sash must be in the CLOSED position in order to begin the reference run. If necessary, slide the sash to this
position manually.
2. Press the
RESET
button; the LED flashes red.
3. Press the operating push button. The reference run starts. During the reference run, the sash is unlocked and then locked
again.
4. Wait approx. 4 - 10 seconds until the sash is locked.
5. The LED switches off once the reference run is complete.
1.
2.
3.
4.
4 - 10 Sek.