Problem
Possible cause
Solution
When operating with optional WIFI
module
(smart modules axxent DK):
DRIVE axxent DK does not respond
to smartphones/ tablets
wiring wrong/defective or cable
defective
check the wiring (see page 12)
no WIFI connection to the router of
the home network
restart WIFI router of the home network
no WIFI connection to the smart-
phone/tablet
restart smartphone/tablet
no WLAN connection to the
DRIVE axxent DK
reset on the DRIVE axxent DK :
1. press “Close” button 3 times quickly in
succession
2. then immediately press and hold the
"Close" button (for approx. 4 seconds)
3. DRIVE axxent DK moves back and forth
quickly before stopping
The module will then return to the default
setting.
DRIVE axxent DK does not move
»OPEN« / »CLOSE«
No power supply
Check the power supply
Hardware is blocked or too stiff
Check manual function of window and
rectify blockage if necessary
Hardware is too easy-running
Increase the compression
Drive is soiled
(sawdust etc.)
Check the drive for soiling and clean if
necessary
Especially for »OPEN« motion:
drive is already in the »Open«
position
Check position of the window sash and
perform reference run if necessary
(see page 20)
Especially for »CLOSE« motion:
drive is already in the »Closed«
position
DRIVE axxent DK beeps several times
and stands still. LED flashes perma-
nently
Strong wind pressure
Wait until the wind pressure subsides
Draught
Rectify reason for the draught
Hardware is blocked or too stiff
Check manual function of window and
rectify blockage if necessary
Power failure
Rectify the power failure and perform
reference run
DRIVE axxent DK beeps several times
and slowly attempts up to 3x to travel
into the »Closed« position (the drive
stands still after the third attempt).
LED flashes permanently
Strong wind pressure
Wait until the wind pressure subsides
Draught
Rectify reason for the draught
Hardware is blocked or too stiff
Check manual function of window and
rectify blockage if necessary
*
Note:
a current measurement is performed on the drive whilst the window is closed in order to prevent operating errors
when the window is open. If you issue an opening command while the window is open, the motor will detect that no hard-
ware is connected. The drive will reverse and return to the starting position.
8.1 SIEGENIA Comfort app
You will find detailed operating information and information on how to rectify malfunctions on the SIEGENIA Smarthome
Internet page.