Only valid for UL 61800-5-1, IEC 61800-5-1 and UL-1004-1.
Technical Considerations:
▸
The equipment under test was tested for use at the maximum ambient temperature
permitted by the manufacturer's specification of: +40 °C.
▸
The maximum operation altitude of the equipment is specified for 1000 m.
▸
The tests were performed at the largest device versions.
Requirements to the power supply unit for SD2B plus
Specifications: AC-DC Industrial DIN rail power supply; NRTL license UL 508 File no.
Exxxxx; IEC / UL / EN 60950-1 / EN 62368-1
▸
The power supply unit shall meet the requirements of the Overvoltage Category III
and Pollution Degree 2: EN 61800-5-1; EN 60950-1 / EN 62368-1
▸
A safe isolation of circuits by means of a basic and additional protection (basic in-
sulation plus insulation or protection shielding) or via an equivalent protection unit,
e.g. reinforced insulation.
▸
Reinforced insulation:
Separate insulation system that is applied for active parts and that provides a level
of protection against electric shock, which is equivalent to the double insulation ac-
cording to the requirements defined in the corresponding IEC 60664-1 (Insulation
coordination for equipment within low-voltage systems).
9
Drive Amplifier SD2B plus - 0362171DA1xxxx, 0362171DB1xxxx
General Information