![SIEB & MEYER 0362171DA1 Series Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/sieb-and-meyer/0362171da1-series/0362171da1-series_hardware-description_1264945045.webp)
8.2
List of Drive Error Messages
Note
The following messages apply to the entire SD2x drive series. According to the device
type or operating mode, certain messages may not appear.
Code
Error message
Error reaction
Possible reason
Interpolation error (interpolated po-
sition control)
1
Acceleration limit exceeded
2
Speed limit exceeded
E03
(0x103)
(259
d
)
3
Index error
Motor is stopped by quick stop
ramp and drive is disabled (con-
trolled standstill).
▸
Faulty motion profile of the high-
er-ranking control
E05
(0x105)
(261
d
)
Error caused by warning
Motor is stopped by quick stop
ramp and drive is disabled (con-
trolled standstill).
▸
Parameter-driven monitoring stopped
the drive.
Digital Input 'External Hardware'
Monitoring of external hardware:
0
Digital input
0
Digital input „External Hardware
OK‟ is not connected to 24 V.
1
Analog input 0: broken cable
1
Minimum current monitoring of ana-
log input 0 has triggered.
2
Analog input 1: broken cable
2
Minimum current monitoring of ana-
log input 1 has triggered.
E06
(0x106)
(262
d
)
3
Analog input 0 and 1: broken
cable
Motor is stopped by parameter-dri-
ven ramp and drive is disabled
(controlled standstill).
3
Minimum current monitorings of
analog inputs 0 and 1 have trig-
gered.
E07
(0x107)
(263
d
)
Error in internal hardware
Motor is stopped by quick stop
ramp and drive is disabled (con-
trolled standstill).
▸
Overload in digital outputs
▸
SD2B plus: Operating voltage not
available
E09
(0x109)
(265
d
)
Hiperface / EnDat OEM data incor-
rect
No "Ready" for startup
▸
Number of motor pole pairs in En-
Dat/Hiperface encoder does not
match the parameter set.
E10
(0x10A)
(266
d
)
drive-setup-tool heartbeat
Motor is stopped by quick stop
ramp and drive is disabled (con-
trolled standstill).
▸
drive-setup-tool
was not able to com-
municate with the drive in the para-
meterized monitoring time.
45
Drive Amplifier SD2B plus - 0362171DA1xxxx, 0362171DB1xxxx
Status Display and Error Messages