![SIEB & MEYER 0362171DA1 Series Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/sieb-and-meyer/0362171da1-series/0362171da1-series_hardware-description_1264945050.webp)
Status Display and Error Messages
Code
Error message
Error reaction
Possible reason
E58
(0x73A)
(1850
d
)
FPGA watchdog triggered
Device stops in BIOS.
▸
FPGA process monitoring has
been triggered;. Please contact
SIEB & MEYER.
E59
(0x73B)
(1851
d
)
No drive parameters loaded
Device stops in BIOS.
▸
Device is not parameterized (status
of delivery).
E60
(0x73C)
(1852
d
)
Drive parameters incorrect
Device stops in BIOS.
▸
Parameter set of the device is not
valid (CRC error).
E61
(0x73D)
(1853
d
)
Logic coding missing or incorrect
Device stops in BIOS.
▸
Logic programming of the device is
not valid.
E62
(0x73E)
(1854
d
)
Error in electronic type plate
Device stops in BIOS.
▸
Type plate is not programmed
or faulty. Please contact
SIEB & MEYER.
(1)
For servo motors with commutation via an incremental motor measuring system, the warning W17 „Unknown commuta-
tion angle‟ is signaled. After a restart of the device the phasing of the motor measuring system starts automatically (magnetic
alignment).
8.3
List of the Warning Messages
Warning messages are not displayed on the device display. They can only be seen in
the software
drivemaster 2
via „Diagnosis → Errors and warnings‟.
Code
Description
W00
Digital input 'Quick stop' active
W01
Digital input 'Positive limit switch' active
W02
Digital input 'Negative limit switch' active
W03
Voltage of mains supply not OK
W04
Power output stage load greater than parameterized warning threshold W04 (power output
stage I²t)
W05
Motor load greater than parameterized warning threshold W05 (motor I²t)
W06
Power output stage temperature greater than parameterized warning threshold W06
W07
Motor temperature greater than parameterized warning threshold W07
W08
DC link voltage greater than parameterized warning threshold W08
W09
DC link voltage less than parameterized warning threshold W09
W10
Speed controller in current limitation / PI limit
W11
Position/tracking error greater than parameterized warning threshold W11
W12
Speed error greater than parameterized warning threshold W12
W13
Tracking error of the current too great
W14
Ambient temperature greater than parameterized warning threshold W14
W15
Ballast resistor load greater than parameterized warning threshold W15 (ballast resistor I²t)
W16
Safety circuit is active
W17
Unknown commutation angle
W18
Hiperface / EnDat OEM data not valid
W19
Dirt signal encoder input 0
W20
Dirt signal encoder input 1
W21
Dirt signal encoder input 2
W22
Power supply unit load greater than 90% of the rated power
W23
Reserved
W24
Current or current rise greater than warning threshold W24 (warning current)
50
Drive Amplifier SD2B plus - 0362171DA1xxxx, 0362171DB1xxxx