![SIEB & MEYER 0362151 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/sieb-and-meyer/0362151/0362151_original-instructions-manual_1264958020.webp)
Connectors, Switches and Displays
6.2
Connector Pin Assignment
6.2.1
X1 – 24 Volts Connector
4-pole Combicon connector MSTB-2,5 (Phoenix)
Pin
I/O
Name
Meaning
1
I
24 V
Logic voltage 18 – 28 volts
2
I/O
GND
Ground
3
n.c.
4
n.c.
6.2.2
X2 – PROFIBUS Slave Connection
9-pole female submin D connector
Pin
I/O
Name
Meaning
1
Shield
Cable shield
2
n.c.
Ground
3
I/O
RxD / TxD-P (B)
Transmit/receive data (PROFIBUS)
4
O
RTS
Request to send
5
I/O
GND
Reference ground for bus termination
6
VCC5
5 V supply voltage for bus termina-
tion
7
n.c.
8
I/O
RxD / TxD-N (A)
Receive / transmit data (slave)
9
n.c.
Stud bolt flange: max. tightening torque = 0.7 Nm
6.2.3
X4/ X3 – SERVOLINK 4
SERVOLINK 4: optical input (X4) and optical output (X3)
The fiber optic connectors for SERVOLINK 4 are located at the bottom side of the de-
vice.
Connector
SIEB & MEYER article number
12540102
Inputs (black)
12540103
12540202
Outputs (gray or white)
12540203
Cable connector
(TOSLINK F05)
32022900
20
Gateway 0362151 - PROFIBUS to SERVOLINK 4 Connection