Previous image
, steps to the previous image and pauses.
First image
, steps to the first image in the series and pauses.
Choose image folder
, lets the user select images to be used in the emulator.
Settings
for viewing the image series, including repeat (on/off) and viewing
time.
7.9.3
Selecting images to be used
Click the
Choose image folder
button to select images to use in the emulator. The images
must be Portable Network Graphics (.png) files acquired by a TriSpector1000.
NOTE
When selecting an image in the
Choose image folder
window, all images in the folder will
be used in the emulator, not only the selected image.
To save images from the TriSpector1000 to PC,
see "Recording images", page 32
7.9.4
Copying a configuration from the emulator
When connected to a TriSpector1000
If the emulator was started by using the
Switch to simulated device
option:
1.
In the SOPAS ET device window, click
Switch to physical device
on the
Device
menu.
When not connected to a TriSpector1000
If the emulator was started from the SOPAS ET main window:
1.
In the SOPAS ET device window, click
Export...
on the
Device
menu.
✓
The
Device Export
window opens.
2.
Save the configuration as a SOPAS ET (.sopas) file.
3.
Connect to the TriSpector1000 from the SOPAS ET main window.
4.
Load the configuration by clicking
Import...
on the
Device
menu.
NOTE
To save an imported configuration in the device´s flash memory, click
Save permanent
on
the
Parameter
menu.
7.10
Exporting and importing data
Use the
Export
and
Import
functions in the SOPAS ET device window to export and import
TriSpector1000 configurations between the device and a PC.
Exporting a configuration to a PC
1.
In the SOPAS ET functions panel, on the
Device
menu, click
Export...
✓
The
Device Export
window opens.
2.
Select file name and destination folder on the PC.
3.
In the
Save as type
list, select
SOPAS (*.sopas) SOPAS ET file
.
4.
Click
Save
.
Importing a configuration from a PC
1.
In the SOPAS ET functions panel, on the
Device
menu, click
Import...
✓
The
Import
window opens.
7
OPERATION
56