General parame‐
ters
1
TMS88B-ALC360
TMM88B-ALC090
Measuring range
360°
±90°
Resolution
0.01°
0.01°
Accuracy
Range
0...360°
Typical
±0.15°
Maximum
±0.25°
Range
up to ±60°
up to ±80°
Typical
±0.10°
±0.20°
Maximum
±0.20°
±0.40°
Cross sensitivity
(compensated)
-
Typ. ±0.10° (±0.11%FS)
Max. ±0.20° (±0.22%FS)
Temperature coeffi‐
cient (zero point)
Typ. ±0.01°/K
Sampling rate
80 Hz
Limit frequency
Typ. 20 Hz, 2nd order (no digital filter) / 0.1 ... 25 Hz, 8th order (with
digital filter)
Operating tempera‐
ture
-40 °C to +80 °C
Properties
Voltage interface
Freely configurable output in the range 0...10.48 V (factory setting:
0...10 V)
Freely configurable angle range 0...360° / ±90°
Functions
Teach input for zero-point setting when installed
Limitation of final value, counting direction, and axis assignment of out‐
puts can be configured
Digital filter (critically damped (default) or Butterworth low pass, 8th order)
Electrical parameters
Supply voltage
16 ... 35 VDC
Current consump‐
tion
35 mA @ 24 V
Outputs (short-cir‐
cuit protected)
Capacitive load less than 1 μF, resistance greater than 1 kΩ
Mechanical parameters
Connection
5-pin M12 sensor plug connector (male connector)
Enclosure rating
IP65/67
Dimensions /
Weight
Aluminum housing: 58 mm x 90 mm x 31 mm / approx. 200 g
1
All specified angular accuracies apply after a run-in time of 10 min at 25 °C, limit frequency 0.3 Hz,
absolute calibration accuracy (at 25 °C): ±0.05°
TECHNICAL DATA
4
8019053/1EF6/2021-12-13 | SICK
O P E R A T I N G I N S T R U C T I O N S | TMS/TMM88, TMS/TMM55
13
Subject to change without notice