LED 表示灯/故障パターン /
LED indicator/fault pattern
原因 /
Cause
対策 /
Acción
Check the operating condi‐
tions: Fully align the beam
of light (light spot) with the
reflector. / Clean the optical
surfaces (sensor and reflec‐
tor). / Readjust the sensitivi‐
ty (potentiometer) / If the
potentiometer is set to the
max. sensing range: Redu‐
ce the distance between
the sensor and the reflec‐
tor, and check the reflector
type against graphic H. /
Reflector is not suitable for
the application in question
(we recommend only using
SICK reflectors) / Check
sensing range and adjust if
necessary; see graphic H. /
Distance between the sen‐
sor and the reflector is too
long / With health output:
Check the power supply,
check all electrical connec‐
tions (cables and plug con‐
nections).
対象物検出時の出力信号が不
安定 /
Signal interruptions when
object is detected
反射に偏りのある対象物表
面(例:テープ等)からの
反射光を無くします /
Depolarizing property of the
object surface (e.g., tape),
reflection
感度を下げるか、またはセ
ンサの位置を変えて下さい /
Reduce sensitivity or
change the position of the
sensor
71
解体および廃棄
センサは必ず該当国の規制にしたがって処分してください。廃棄処理の際には、
できるだけ構成材料をリサイクルするよう努めてください(特に貴金属類)。
72
メンテナンス
SICK センサはメンテナンスフリーです。
定期的に以下を行うことをお勧めしています:
•
レンズ境界面の清掃
•
ネジ締結と差込み締結の点検
機器を改造することは禁止されています。