No.
Requirement
Comment
Result OK?
8.3
If the Timing Set Selection func‐
tion is used:
Are n
counter
function blocks in
the
Min time monitoring
network
configured for the minimum dura‐
tion of the muting function?
Yes
⃞
No
⃞
9.1
Are all overflow values of the
counter function block in the
Max
time monitoring
network set to a
value that results in a time shorter
than 10 min?
Yes
⃞
No
⃞
9.2
If the Timing Set Selection func‐
tion is used:
Are n
counter
function blocks in
the
Max time monitoring
network
configured for the maximum dura‐
tion of the muting function?
Yes
⃞
No
⃞
10
Are additional safety functions
exclusively implemented in the
Flexi Soft on separate logic pages
without influencing the Safe Entry
Exit safety system?
Yes
⃞
No
⃞
ANNEX
15
8021675/ZV26/2019-05-13 | SICK
O P E R A T I N G I N S T R U C T I O N S | Safe Entry Exit
51