6
Electrical installation
NOTE
Information is included in the operating instructions for the components.
6.1
General requirements
The following measures to prevent common-cause failures must be considered during
electrical installation:
•
Separation of the signal pathways for the safety system signals, e.g. by laying sep‐
arate cables or shielding the signal paths separately.
•
Protection against overvoltage, overcurrent, etc. according to the manufacturer’s
instructions for the individual components.
•
Mechanical fastening of the wiring of the pushbutton for the manual muting
device, e.g. with cable ties.
•
Measures for controlling the consequences of voltage failure, voltage fluctuations,
overvoltage and undervoltage in the voltage supply of the process controller.
6.2
Safety controller pin assignment
Figure 3: Safety controller setup
ELECTRICAL INSTALLATION
6
8021675/ZV26/2019-05-13 | SICK
O P E R A T I N G I N S T R U C T I O N S | Safe Entry Exit
23