4
Project planning
4.1
Manufacturer of the machine
DANGER
Hazard due to lack of effectiveness of the protective device
In the case of non-compliance, it is possible that the dangerous state of the machine
may not be stopped or not stopped in a timely manner.
b
Use of the safety system requires a risk assessment. Check whether additional
protective measures are required.
b
Comply with the applicable national regulations derived from the application (e.g.,
work safety regulations, safety rules, or other relevant safety guidelines).
The safety system was developed under consideration of typical application cases. A
partial safety function can be implemented with the safety system in these application
cases. The manufacturer must check whether the safety system is suitable for its spe‐
cific application case (risk assessment).
If the thorough check shows that the safety system is not suitable for the specific appli‐
cation case, the safety system can be used as a basis for an individualized develop‐
ment suitable for the specific application case. This case will not be considered further
in this document.
In any event, additional work is necessary for the safety system to be used, e.g. subse‐
quent configuration of the safety controller.
The manufacturer has the following duties:
b
Executing a risk assessment.
b
Verifying and validating the safety functions.
b
Integrating the individual components in accordance with the appropriate stan‐
dards.
b
Please note that C standards have priority compared to statements about this
safety system.
4.1.1
Calculation of the performance level
Complete subsystems for SISTEMA available on the internet for this safety system can
be used to calculate the achieved performance level.
Three subsystems are available:
•
Safe Entry Exit with a standard control as a higher-level control (requirements
"Requirements for the higher-level control", page 13
)
•
Safe Entry Exit with a safety controller as a higher-level control (requirements
"Requirements for the higher-level control", page 13
)
•
A separate subsystem for the hold to run device
WARNING
Certain indicators for the individual components were used as the basis for calculating
the values for the subsystems. Accordingly, the subsystems are only valid if the selected
components of the safety system meet all requirements,
.
During the development of the safety system, certain measures against common-cause
faults were implemented or defined. Some of these measures must be taken into
account during implementation,
see "General requirements", page 23
.
4
PROJECT PLANNING
16
O P E R A T I N G I N S T R U C T I O N S | Safe Entry Exit
8021675/ZV26/2019-05-13 | SICK