2
Hold function
3
Duration of measurement
4
Internal measured value
5
Output hold value
7.3.6.3
Setting the alarm (action in case of incorrect measurements)
This function allows you to determine the output when a measurement is not possible.
Table 14: Settings for action in case of incorrect measurements
Setting
Meaning
User-defined value
A defined value is displayed
Hold last value
The most recently measured value is displayed
User-defined value at a set
time
Forces the output of a user-defined value at a set time during an
incorrect measurement
Action in case of incorrect measurements: User-defined value
The user-defined value is set in the section on
Action in case of incorrect measurements
.
Values
±
2,147,483 mm are possible; the default value is 1.00 mm.
NOTICE
If the
AOD1
setting is selected for
Input terminal
under
Communication
, the user-defined
value is automatically adjusted to the following value:
209.7152 mm
This value must not be modified.
Error suppression time
When
User-defined value at a set time
is selected, then the number of measuring points is
determined under
Error suppression time
, during which the most recently measured value
is displayed. If a measurement still cannot be taken after this period then the user-
defined value is displayed.
Values are possible from 0 (default value) to 4,095.
Restoration period following an error
When
User-defined value at a set time
is selected, then the number of measuring points is
determined under
Restoration period following an error
. The user-defined value is continued
to be output although a measurement is possible again.
Values are possible from 0 (default value) to 4,095.
OPERATION
7
8021391//2017-10-06 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD5000
41
Subject to change without notice