Connection
1
to the Y-distribution
Table 2: Pin assignment on 4-pin M12 male connector
Pin
Signal
Function
1
24 V
Voltage supply
2
Input (MF) / RS485+
Input MF (NPN) / Reserved
3
0 V
Voltage supply
4
Input (MF) / RS485-
Input MF (PNP) / Reserved
-
Shield
-
1
4
3
5
2
Figure 22: Female connector, M12, 5-pin, D-coded
Connection
2
to the Y-distribution
Table 3: Pin assignment on 5-pin M12 female connector
Pin
Signal
Function
1
TxD+
Network interface
2
RxD+
Network interface
3
TxD-
Network interface
4
RxD-
Network interface
5
NC
Not connected
-
Shield
-
1
7
2
6
3
4
5
8
Figure 23: Female connector, M12, 8-pin, A-coded
Connection
3
to the Y-distribution
Table 4: Pin assignment on 8-pin M12 female connector
Pin
Signal
Function
1
Input (MF) / RS485+
Input MF (NPN) / Reserved
2
0 V
Voltage supply
3
24 V
Voltage supply
4
TxD-
Network interface
5
RxD+
Network interface
6
TxD+
Network interface
7
Input (MF) / RS485-
Input MF (PNP) / Reserved
8
RxD-
Network interface
-
Shield
-
ELECTRICAL INSTALLATION
6
8021391//2017-10-06 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD5000
25