7.4.2.1
Outputting measured values
Table 27: Command list for sensor status and measured values
Access Command
Name
Parameter
Comments
R
0x0D60
Value of channel A dis‐
placement
R
0x0D64
Value of channel B
displacement
R
0x0D68
Value of channel C dis‐
placement
R
0x0D6C
Value of channel D
displacement
R
0x0DA0
Channel A output sta‐
tus
*1
R
0x0DA4
Channel B output sta‐
tus
*1
R
0x0DA8
Channel C output sta‐
tus
*1
R
0x0DAC
Channel D output sta‐
tus
*1
R
0x01F4
Sensor status
*2
Explanation of the bits relating to *1
Table 28: Explanation of the bits relating to *1
Bit
Comments
32
(not used)
...
16
(not used)
15
(not used)
14
(not used)
13
(not used)
12
(not used)
11
HI output
10
GO output
9
LO output
8
(not used)
7
(not used)
6
Hold ON
5
Zero set ON
4
(not used)
3
ON if measurement not possible
2
Control input/output status (ON/OFF)
1
Channel usage
Explanation of the bits relating to *2
Table 29: Explanation of the bits relating to *2
Bit
Comments
32
(not used)
OPERATION
7
8021391//2017-10-06 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD5000
55
Subject to change without notice