7.2.2
Operating elements
Table 9: Functions of the reset pushbutton
Hold down pushbut‐
ton for
Function
LED status
Description
< 1 s
None
Unchanged
Changes are not
adopted if pushbutton
is not pressed for long
enough
1 to 5 s
IP address is initial‐
ized (static IP)
Flashing orange
(slowly)
IP address is changed
to 192.168.0.01
5 to 10 s
IP address is changed
(DHCP)
Flashing green (slowly) IP address is obtained
and set to DHCP
> 10 sec
All settings are initial‐
ized
Flashing green
(quickly)
All settings are reset
to the factory settings
NOTE
■
Press reset pushbutton to reset all settings to factory settings.
The reset pushbutton is only accessible once the screw has been removed.
■
Always remove and store the screw together with the sealing ring.
■
Refit the screw and sealing ring.
■
Observe the maximum torque of 0.08 Nm
±
20%.
The IP67 enclosure rating is only ensured with a proper screw connection and intact
sealing ring.
7.3
Operation via web browser (SOPASair)
7.3.1
Determining the device IP address
DHCP is preset on the device as standard meaning that the IP address is obtained
automatically.
In order to ascertain the IP address assigned to the device, please contact the relevant
network administrator or use SOPAS ET.
The device IP address can also be verified and adjusted by a device-specific search in
SOPAS ET.
The most up-to-date version of the software is available at:
b
7.3.2
Connecting via the web browser
The following browsers are supported:
•
Internet Explorer (version 11 or higher)
•
Google Chrome (version 49 or higher)
1.
Start browser.
2.
Enter the device IP address.
✓
The SOPASair settings screen is displayed.
OPERATION
7
8021391//2017-10-06 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD5000
29