7
Operation
7.1
General notes
If the device is not able to perform a measurement even though the measuring object is
within the specified measuring range, the alignment should be checked and optimized
if necessary. In general, adjusting the measuring rate can increase the measuring abil‐
ity for very dark objects, for example.
For a successful teach operation, the device must be able to measure. The distance to
the teach object must not change during the teach operation. The object must be in the
measuring range, and the distance values taught in for the distance near to the sensor
and the distance far from the sensor must not be exactly the same during a switching
window or the analog scaling.
To prevent EMC interference, observe the wiring instructions. If an environment is dis‐
rupted by EMC interference, data output via IO-Link is the preferred solution. If the
application requires an output of the measured values in such an environment via the
analog output, an analog current output should also be preferred to using the voltage
output, because this is significantly less susceptible to EMC interference.
7.2
Control elements and status indicators
7.2.1
Indicator lights
PWR
Q1
Q2
1
4
2
3
1
Status-LED PWR (grün)
2
Status-LED Q1 (orange)
3
Status-LED Q2 (orange)
4
Bedientasten
Table 3: Meaning of the indicator lights
Display
Status
Meaning
PWR status indicator
O
Voltage supply available, device
ready for use
o
Voltage supply not available
Ö
Voltage supply available, device
ready for use, connection to an IO-
Link master available
Output display Q
1
O
Switching output active
o
Switching output not active
Output display Q
2
O
Switching output active or measured
value within the scaling range for the
analog output
o
Switching output not active or meas‐
ured value outside the scaling range
for the analog output
7
OPERATION
20
O P E R A T I N G I N S T R U C T I O N S | OD1000
8019642/ZJW1/2017-04-03 | SICK