Fixed setting: The device uses the set cycle time as a maximum, regardless of the
object surface. The output rate of the measured values corresponds to the set
value and remains constant.
NOTE
If the remission properties of the object are not sufficient to perform a valid meas‐
urement, the device outputs the value of an incorrect measurement,
case of incorrect measurements", page 36
>
Measurement
>
>
Default settings
>
>
Cycle time
>
Parameter
Factory setting
Auto, 0.3 ms, 0.5 ms, 1 ms, 5 ms, 10 ms
Auto
8.3.2.2
Measured value filter
The measured value filters are used to optimize the signal diagram in order to simplify
the evaluation by the control system, e.g., for regulation tasks.
•
Averaging filter: The averaging filter carries out a moving averaging of the meas‐
ured values. This filter is suitable for smoothing a noisy signal diagram. This
improves the reproducibility of the device.
•
Median filter: The moving median filter sorts the measured values according to
their size and selects the middle value from a sequence. This filter is suitable for
excluding individual outliers from the calculation of an average value.
Both types of filter affect the response time of the distance sensor.