Parameter
Factory setting
-1,000.0 m ... +1,000.0 m
-600.0 m
Teaching in the zero point
The current distance is taught in as a new zero point (reference point). When the analog
output is activated, the analog value is set to the center of the measuring range at this
distance (12 mA / 5 V).
>
Measurement
>
>
Default settings
>
>
Measured value offset
>
>
Teach in zero point
>
NOTE
This function can also be executed using a shortcut:
b
In the main display level, press and hold the pushbutton for > 3 seconds until
the relative distance value is set to 0.0 mm
Resetting the zero point
This resets the zero point to the center of the measuring range according to the factory
setting.
>
Measurement
>
>
Default settings
>
>
Measured value offset
>
>
Reset zero point
>
NOTE
This function can also be executed using a shortcut:
b
In the main display level, press and hold the pushbutton for > 6 seconds until
the relative distance value is set to the factory setting.
8.3.2.6
Action in case of incorrect measurements
If a distance measurement cannot be run, an error is output. Possible causes of the
error:
•
The measuring object is outside of the measuring range.
•
The light signal received by the device is not strong enough.
•
The laser is switched off.
You can configure the device behavior for the event that no measurement is possible.
The following options are available:
•
Substitute value in the event of an error
: A numerical value can be entered which
is output when no measurement is possible.
•
Error mode
>
User-defined values
: If no measurement is possible, the set
Substi‐
tute value in the event of an error
(see above) is displayed and held until a valid
measured value is available again.
•
Error mode
>
Hold last value
: If no measurement is possible, the last valid meas‐
ured value is displayed and held until a valid measured value is available again.
8
OPERATION VIA DISPLAY
36
O P E R A T I N G I N S T R U C T I O N S | OD1000
8019642/ZJW1/2017-04-03 | SICK
Subject to change without notice