13
Technical data
Table 12: Technical data
Cylinder type
C-slot
Detection zone
0 ... 50 mm
1)
Supply voltage U
B
10 ... 30 V DC
Power consumption
≤ 550 mW
Required magnetic field strength, typ.
≥
2 mT
overrun distance
can be configured
Hysteresis
can be configured
Time delay before availability
0.15 s
Resolution typ.
0.01 mm
Linearity typ.
0.3 mm
2)
0.05 mm
3)
2 kHz
IO-Link
1.1
Enclosure rating
IP67
Protection class
III
Circuit protection
A, B, D
4)
Ambient temperature, operation
–20 °C ... +70 °C
1)
Deviations are possible depending on the drive.
2)
At 25 °C, the linearity error (maximum deviation) depends on response curve and minimum deviation
function.
3)
At 25 °C, repeatability with magnet movement from one direction.
4)
A = UB connections reverse polarity protected
B = Inputs and outputs reverse polarity protected
C = Interference suppression
D = Outputs overcurrent and short-circuit protected
TECHNICAL DATA
13
8025942/2020-07-16 | SICK
O P E R A T I N G I N S T R U C T I O N S | MPS-G with 2 / 3 switching points and IO-Link (up to 16 switching points)
41
Subject to change without notice