Move
Q2
PW
R
Q1
Q2
PW
R
Q1
s
s
s
Q2
PW
R
Q1
s
s
Q2
PW
R
Q1
f
f
Regular Operation
Teach Menu
Dynamic Teach
Enter Teach
Menu
2x
ca.
0.5 sec
(short)
1x
ca.
0.5 sec
(short)
Enter Manual
Teach menu
1x
ca.
1.5 sec
(long)
Start
1x
ca.
1.5 sec
(long)
Finish Teach
→ Save changes
→ Exit teach menu
→ Q1-LED lights up for Qint1,
Q2-LED lights up for Qint2,
Q1- and Q2-LED light up
same time for Qint3
Move piston and stop at
desired position for Qint*
→ Qints are set at v = 0 m/s
(up to 3 Qints possible)
End
No stops found?
→ Exit teach menu
without changes
8
OPERATION
30
O P E R A T I N G I N S T R U C T I O N S | MPS-G with 2 / 3 switching points and IO-Link (up to 16 switching points)
8025942/2020-07-16 | SICK
Subject to change without notice