Exit teach menu
without changes
→ Q1-LED lights up for Qint1,
Q2-LED lights up for Qint2,
Q1- and Q2-LED light up
same time to Qint3
1x
3 - 5 sec
(very long)
Delete
Qint
Action not preformed if button is released before
request time start
Reset Menu
Action preformed if button is
released within request time
Action not preformed if button is
released after request time end
0 sec
1 sec
1.2 sec
3 sec
5 sec
time
LED behaviour
Off
On
Slow blink
Inverted slow blink
Fast blink
Inverted fast blink
Tallymark blink
*** width of switch points can
only be adjusted seperately. After
adjusting width of one Qint the menu
ist left. For adjusting the width of the
second and/or third Qint menu has to
be entered again.
**** width can be adjusted 1 mm steps
(1 ... 5 mm). Default setting of width is 2 mm.
By pushing the button once width ist
increased from 2 to 3 mm (and so on).
Qint
successfully deleted
Figure 12: Teach routine for switching point width
Flashing tally sheet:
1 mm = 1 x brief flash
2 mm = 2 x brief flashes
3 mm = 3 x brief flashes
4 mm = 4 x brief flashes
5 mm = 1 x long flash
8.4
Diagnostic function
During the application, the MPS-G Smart Sensor also monitors:
•
Cycle count
•
Travel time
•
Cylinder travel
OPERATION
8
8025942/2020-07-16 | SICK
O P E R A T I N G I N S T R U C T I O N S | MPS-G with 2 / 3 switching points and IO-Link (up to 16 switching points)
35
Subject to change without notice