ON
Qint SP
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
1
2
1
3
Figure 6: Switching behavior after
Manual Teach
1
Hysteresis
2
Width of the switching point
3
Position
There is no
during manual teach-in of the switching points. The switching
point width is 2 mm according to the factory setting and can be adjusted via the Teach
menu (1 – 5 mm).
3.3.5
Switching behavior after Dynamic Teach of 2 switching points
If the sensor, during Dynamic Teach, detects teach 2 x piston status v = 0, 2 switching
points are set.
NOTE
only start working from a speed of v > 25 mm/s.
Example: Arrangement of switching points for dynamic teach-in of 2 switching points
on a pneumatic cylinder
The 2 switching points are always arranged as follows during dynamic teach-in: Qint1
lies in the direction of the cable outlet and Qint2 in the direction of the sensor fixing
screw. It does not matter which position is approached first.
Table 2: Switching behavior with 2 switching points
1.) Output position v= 0.
No switching point is
defined at the output posi‐
tion of the magnet.
v = 0
PRODUCT DESCRIPTION
3
8025942/2020-07-16 | SICK
O P E R A T I N G I N S T R U C T I O N S | MPS-G with 2 / 3 switching points and IO-Link (up to 16 switching points)
13