8
Operation
8.1
General notes on operation
Teach possible using teach-in button.
NOTE
The user is responsible for the correct teach process.
IO-Link
In addition to manual configuration, the sensor can also be configured using IO-Link. A
detailed list of IO-Link functions can be found in the leaflet and can be downloaded at
.
You can find the IODD file at
.
The following settings can be made and parameters read out via IO-Link:
•
Configuration of up to 16 switching points (Qints)
•
Position determination in mm
°
°
•
Pneumatic Actuator Diagnosis
: Read out of the following data:
°
°
°
Total cylinder travel in [m]
°
°
Stroke time in [ms] (stroke time in positive direction / stroke time in negative
°
Stroke speed in [m/s] (stroke speed in positive direction / stroke speed in
negative direction)
°
Dwell time in start position in [ms]
°
Dwell time in end position in [ms]
°
Currently measured field strength per sensor element in [mT]
°
Measured peak value of the field strength per sensor element in [mT]
8.2
Operating and status indicators
8.2.1
Control element
The following settings can be made via the teach-in button.
•
Definition of up to 3 switching points (digital outputs) via
Dynamic Teach
function
•
Manual definition of 1 to 3 switching points (digital outputs)
•
Adjustment of overrun distance per switching point (1 – 5 mm) (after
Manual Teach
)
•
Deactivation of all switching points
8
OPERATION
26
O P E R A T I N G I N S T R U C T I O N S | MPS-G with 2 / 3 switching points and IO-Link (up to 16 switching points)
8025942/2020-07-16 | SICK
Subject to change without notice