The Ethernet interface allows the configuration of the device as well as the output of
measured values.
The factory setting for the Ethernet interface is as follows:
•
IP address: 192.168.0.1
•
Subnet mask: 255.255.255.0
•
TCP port: 2111
You might need to adjust the TCP/IP configuration of the Ethernet interface so that a
connected computer (client) can communicate with the device via Ethernet:
Project tree
,
LMS…
,
Network/Interfaces/IOS
,
Ethernet
.
NOTE
If you change the parameters of the Ethernet interface via the Ethernet interface, you
must first save the data permanently to non-volatile memory in the device and then
restart the device. A
Restart
button is available in SOPAS ET for this purpose.
The description of the electrical interface
.
Serial host interface
The Serial Host Interface is an RS-232 / RS-422 interface. The host interface permits
the configuration of the device and limited output of measured values.
The interface parameters are freely configurable: SOPAS
Project tree
,
LMS…
,
Net‐
work/Interfaces/IOS
,
Serial
,
Serial HOST Interface
section.
The factory setting for the host interface is as follows:
•
57.6 kBd
•
8 data bits
•
1 stop bit
•
No parity
NOTE
If you change the parameters for the host interface via the host interface, the connec‐
tion to the device will be lost. You must then scan for the device again in SOPAS ET (
).
A description of the electrical interface
USB auxiliary interface
The Mini-USB auxiliary interface permits direct configuration of the device.
NOTE
To access the device via the USB auxiliary interface, the required USB driver must first
be installed on the computer. Available as a download at:
.
Parameters can be changed via USB while the device is connected to a host via another
interface such as RS or Ethernet. Only the last changes saved in the configuration, both
via USB and via RS or Ethernet, are retained.
3.10
Communicating data via telegrams
The device sends telegrams over the interfaces described above to communicate with a
connected host. The following functions can be run using telegrams: