6.4
Connections
6.4.1
Connections of the LMS500
LMS500 Lite and PRO Indoor: “Ethernet” connection on system plug
Table 18: LMS500 Lite and PRO Indoor: Pin assignment of the “Ethernet” connection
Male/female connec‐
tor
Contact
Short form
Signal description
1
4
3
2
Figure 38: M12
female connector, 4-
pin, D-coded
1
TX+
2
Rx+
R
3
TX–
Sender–
4
Rx–
Receiver–
LMS500 Lite Indoor: “Power/Data/I/O” connection in system plug
Table 19: LMS500 Lite Indoor: Terminal assignment of the “Power/Data/I/O” connection
Male/female connector
Contact
Short form
Signal description
Figure 39: 2 x terminal strip,
8-pin
01
V
S
Sensor supply voltage
02
GND
Ground sensor
03
OUT1
Digital output 1
04
OUT2
Digital output 2
05
OUT3 / OUT Sync
Digital output 3 / Synchronization output
06
IN1
Digital input 1
07
IN Sync
Synchronization input
08
GND IN /IN Sync
Ground of digital input 1 / synchronization
input
09
V
S
OUT
Digital output supply voltage
10
GND V
S
OUT
Supply voltage ground of digital outputs
11
TD+
RS-422 sender
12
TD–/TxD
RS-422 / RS-232 sender
13
GND RS
RS-422/RS-232 ground
14
RD–/RxD
RS-422/RS-232 receiver
15
RD+
RS-422 receiver
16
RS shield
RS-422/RS-232 screen
6
ELECTRICAL INSTALLATION
56
O P E R A T I N G I N S T R U C T I O N S | LMS5xx
8013796/1ALS/2021-03 | SICK
Subject to change without notice